← Back to the study · · Download slide

Journal club handout · Anaesthesia · 2024-07-28

Tracheal tube introducer-associated airway trauma: a systematic review

Key result: Tracheal tube introducers were associated with lower airway trauma rates compared to no device

Systematic review of 16 randomized controlled trials and 5 observational studiesMixed results
What is the incidence of airway trauma associated with tracheal tube introducers?
Who
10,797
Patients undergoing airway management
Compared
standard stylets: 13.1% (4.2-31.4 [0.5-79.2])%
bougies: 5.4% (0.4-49.9 [0.0-68.0])%
Main outcome
incidence of airway trauma
Bottom line: Other introducers appear safe and reduce airway trauma risk, though standard stylets might increase it.
Limitation: Heterogeneity in patient characteristics and high risk of bias in many randomized trials.
Anaesthesia · 2024-07-28 · Save PNG

Key points

Limitation the authors note: The quality of evidence was modest and many randomized trials were at high risk of bias due to non-robust measurement of the outcome.

Discussion prompts

  1. Would these patients look like yours? Who was left out?
  2. Is the main outcome one that matters to patients?
  3. Is the difference large enough to change what you do?

Cite: Boulton AJ, Smith E, Yasin A, Moreton J, Mendonca C. Tracheal tube introducer-associated airway trauma: a systematic review. Anaesthesia. 2024;79(10):1091-1101. doi:10.1111/anae.16379