Hybrid closed-loop insulin delivery increased time in target glucose range for young children
Trial of Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes
Clinical question: Does hybrid closed-loop insulin delivery improve glycemic outcomes in young children with type 1 diabetes?
Why it matters: The efficacy and safety of starting a closed-loop insulin delivery system virtually are currently unclear for young children with type 1 diabetes.
- Researchers studied 102 children aged 2 to 5 years with type 1 diabetes, comparing a closed-loop insulin delivery system to standard care.
- The closed-loop group spent 69.3±11.1% of time in the 70 to 180 mg per deciliter target range compared to 55.9±12.6% in the standard-care group.
- The closed-loop group had two cases of severe hypoglycemia and one case of diabetic ketoacidosis, while the standard-care group had one case of severe hypoglycemia.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Wadwa RP, Reed ZW, Buckingham BA, et al. Trial of Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes. N Engl J Med. 2023;388(11):991-1001. doi:10.1056/NEJMoa2210834