Ultra-High-Resolution Photon-Counting CT Angiography for Noninvasive Detection of Neurovascular In-Stent Restenosis
Abstract
Background
Noninvasive detection of neurovascular in-stent restenosis (ISR) remains challenging because of blooming artifacts and limited spatial resolution on conventional computed tomography angiography (CTA). Ultra-high-resolution (UHR) photon-counting detector CTA (PCD-CTA) may offer an improved approach for accurate ISR detection, potentially overcoming these challenges. Methods
In this prospective study, consecutive patients who had undergone neurovascular stent implantation were enrolled at The First Affiliated Hospital of Nanjing Medical University between July and November 2025. All participants underwent UHR PCD-CTA. Simulated energy-integrating detector CTA data sets were reconstructed from the same raw data to approximate conventional CTA for comparison. Two blinded radiologists independently assessed subjective image quality, diagnostic confidence for ISR, and visualization of in-stent intimal hyperplasia and low-attenuation plaque in stents without restenosis. Diagnostic performance for ISR detection was evaluated on a stent-based level, using digital subtraction angiography as the reference standard when available. Results
Forty-three participants (mean age, 63.1 years ± 9.5; 8 women) with 51 stents were included. ISR was present in 14 stents and absent in 37; digital subtraction angiography was available for 26 stents, including all stents with ISR. Compared with simulated energy-integrating detector CTA, UHR PCD-CTA demonstrated significantly higher subjective image quality (P=0.004) and diagnostic confidence for ISR (PConclusions
UHR PCD-CTA demonstrates high diagnostic performance for noninvasive detection of neurovascular ISR and may serve as a promising tool for poststent surveillance.
Topics
Spotted a mistake? Suggest a correction