Standardized ultrasound screening for vasa previa shows high detection rates and perinatal survival
Ultrasound screening for vasa previa: a systematic review and meta-analysis
Meta-analysis of 19 cohort studiesKey finding
Does standardized ultrasound screening detect vasa previa and improve perinatal survival?
Who
779845
779,845 pregnancies with 505 vasa previa cases
Compared
Standardized ultrasound screening: 98.15% (95% confidence interval, 88.30% to 100.00%) survival
Total pregnancies screened: 494 (97.8%) diagnosed prenatally
Main outcome
prenatal detection and perinatal survival
Result: sensitivity 1.00 (95% confidence interval, 0.99-1.00); specificity 1.00 (95% confidence interval: 1.00-1.00)
Bottom line: Standardized ultrasound screening provides high detection rates and high perinatal survival for vasa previa with minimal errors.
AJOG · 2025-08-07 · Save PNG
Clinical question: Does standardized ultrasound screening detect vasa previa and improve perinatal survival?
Key points
- Researchers analyzed 19 studies involving 779,845 pregnancies and 505 vasa previa cases to evaluate ultrasound screening protocols.
- The pooled sensitivity and specificity for standardized second-trimester ultrasound screening were both 1.00, with only 11 false positives.
- Prenatal diagnosis was associated with a pooled perinatal survival rate of 98.15%.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Donovan B, Bonanni G, Javinani A, et al. Ultrasound screening for vasa previa: a systematic review and meta-analysis. Am J Obstet Gynecol. 2025;233(6):591-603.e9. doi:10.1016/j.ajog.2025.08.003
Spotted a mistake? Suggest a correction