Adding ultraviolet-C light to room cleaning did not reduce specific infection rates in hospital units
Ultraviolet-C Light Evaluation as Adjunct Disinfection to Remove Multidrug-Resistant Organisms
Why it matters: It was unknown if adding ultraviolet-C light to daily and discharge cleaning reduces healthcare-associated infection rates of vancomycin-resistant enterococci and Clostridioides difficile in immunocompromised adults.
- Researchers conducted a cluster randomized crossover trial in 5 hospital units for immunocompromised adults to see if adding ultraviolet-C light to cleaning changed infection rates.
- The addition of ultraviolet-C light was not associated with a change in vancomycin-resistant enterococci infections, which occurred at 6.52 per 1000 patient-days compared to 6.68 in the control group.
- Clostridioides difficile infection rates were 3.78 per 1000 patient-days with ultraviolet-C light compared to 2.64 per 1000 patient-days in the control group.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Rock C, Hsu YJ, Curless MS, Carroll KC, Ross Howard T, Carson KA. Ultraviolet-C Light Evaluation as Adjunct Disinfection to Remove Multidrug-Resistant Organisms. Clin Infect Dis. 2021. doi:10.1093/cid/ciab896
Spotted a mistake? Suggest a correction
The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.