Validation of the Reaction Time-Based False-Positive Rate as a Reliability Index for Standard Automated Perimetry

Nomoto H, Okuyama S, Matsumoto C, Kimura T, Yoshikawa K, Mizoue S, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose To validate a reaction time (RT)-based false-positive rate (RT-FP) for standard automated perimetry (SAP) and to determine the optimal RT listening window. Design Retrospective cross-sectional study. Participants A total of 1201 eyes from 607 glaucoma patients tested with the AIZE algorithm (imo perimeter, 24plus[1-2] pattern). Methods Reaction time-based FP rate was defined as the proportion of stimulus responses below a defined RT listening window, excluding catch trials. Listening windows of 100, 200, and 300 ms were compared using receiver operating characteristic (ROC) analysis against conventional catch-trial FP rate ≥15%. The effect of excluding responses at locations with estimated threshold ≤0, ≤5, ≤10, and ≤15 dB on the association between RT-FP and disease severity was evaluated using Spearman correlation with mean deviation (MD). Relative variability of each FP index was assessed using the coefficient of variation (CV). Main outcome measures Area under the ROC curve (AUC) for discriminating conventional FP ≥15%, Spearman correlation with MD and CV. Results A 300-ms listening window achieved the highest discriminative accuracy (AUC = 0.783), outperforming 200-ms (AUC = 0.733) and 100-ms (AUC = 0.718) listening windows (both P Conclusion Reaction time-based FP rate with a 300-ms listening window restricted to locations with estimated threshold >10 dB substantially reduced metric dependence on disease severity to levels comparable to conventional FP, with greater measurement stability and no requirement for dedicated catch trials. This optimized RT-FP represents a promising reliability index for SAP warranting prospective validation. Financial disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

DOI: 10.1016/j.xops.2026.101347 · PubMed: 42676614

Spotted a mistake? Suggest a correction

More in Ophthalmology

Am J Ophthalmol · Nov 20, 2026 · Research · Pediatric · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

JAMA Ophthalmol · Nov 19, 2026 · Randomized trial · Pediatric · Ophthalmology Visual abstract

Higher concentration atropine drops slowed myopia progression in children

Am J Ophthalmol · Nov 19, 2026 · Research · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Ophthalmology · Nov 18, 2026 · Research · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Am J Ophthalmol · Nov 18, 2026 · Research · Ophthalmology

Static perimetry thresholds developed to assess visual field loss severity in retinitis pigmentosa patients