Validity and Reliability of the CVI Range for Clinical Research: Baseline and One-Year Results
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Purpose
Cerebral/cortical visual impairment (CVI) is a leading cause of visual impairment in children and significantly impacts both visual function and functional vision (the ability to use vision during everyday activities). We developed the CVI Range for Clinical Research (CVI Range-CR), a functional vision assessment that can be incorporated in CVI clinical trials. Herein we evaluate the psychometric properties, interrater and intrarater reliability, and validity of the CVI Range-CR. Design
A prospective, longitudinal cohort study. Participants
Forty children with CVI. Methods
Participants underwent CVI Range-CR assessments at baseline and 1-year follow-up. All assessments were recorded. A trained in-person examiner scored in-person assessments; 2 expert remote graders scored recorded assessments. Visual acuity was evaluated by a pediatric neuro-ophthalmologist using the 6-level visual behavior scale (VBS). Main outcome measures
The CVI Range-CR scores (ranging from 0 to 10) using the Across-CVI Characteristics (rating 1) and Within-CVI Characteristics (rating 2) methods of scoring were compared among graders using the intraclass correlation coefficient (ICC) to assess interrater reliability. A subset of videos was scored twice by the same remote examiner to assess intrarater reliability using the ICC. The CVI Range-CR scores were compared to VBS scores (Spearman's correlation coefficient, ⍴) to evaluate validity. McDonald's ω was used to assess internal consistency of the 10 items on the Within-CVI Characteristics scale. Results
The CVI Range-CR demonstrated high internal consistency (McDonald's ω = 0.96), excellent intrarater reliability (ICC = 0.88-0.98), good-to-excellent interrater reliability (ICC = 0.74-0.88), and strong correlation to clinical assessment of visual behavior as measured by VBS scores (Spearman's ⍴ = 0.76-0.86, P Conclusions
The CVI Range-CR is a reliable and valid measure of functional vision in children with CVI. Because intrarater reliability exceeds interrater reliability, longitudinal studies are recommended to use consistent graders over time. This could be accomplished by remote grading of recorded assessments via a centralized reading center. Financial disclosures
Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.
Cite this article
Chang MY, Reid MW, Roman-Lantzy C, Contractor D, Granger K, O'Neil SH. Validity and Reliability of the CVI Range for Clinical Research: Baseline and One-Year Results. Ophthalmol Sci. 2026. doi:10.1016/j.xops.2026.101233
Spotted a mistake? Suggest a correction