Visual abstractsVisuals
ResearchAnnals of Thoracic Surgery · Jun 5, 2026

Valve Oversizing and Geometric Factors in Structural Valve Deterioration After Pulmonary Valve Replacement

Kugo Y, Kido T, Komori M, Kawai S, Takehara T, Nagashima T, et al
Cardiothoracic & Vascular SurgeryAdult and pediatric

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background Valve oversizing has been associated with structural valve deterioration after pulmonary valve replacement, but the mechanism is unclear. We investigated whether geometric relationships between the implanted valve and the right ventricular outflow tract contribute to structural valve deterioration. Methods We retrospectively analyzed patients with congenital heart disease who underwent pulmonary valve replacement with a bioprosthetic valve in the native right ventricular outflow tract and had postoperative computed tomography. Four geometric parameters were quantified. Valve oversizing was assessed by indexing the true internal diameter of the valve to body surface area. Structural valve deterioration was defined as moderate or greater pulmonary regurgitation or pulmonary stenosis with peak transvalvular velocity ≥3.0 m/s. Associations were evaluated by competing risk regression. Results Eighty-two patients were included, with a median follow-up of 7.2 years. Freedom from structural valve deterioration was 84% at 5 years and 65% at 10 years. Posterior angulation of the implanted valve was associated with structural valve deterioration and remained an independent predictor in multivariable analysis (adjusted hazard ratio, 83.5; 95% CI, 3.61-1930). Posterior angulation correlated with valve oversizing (r = 0.23; P = .04). A posterior angulation index cutoff value of 0.27 provided optimal discrimination for the risk. Conclusions Prosthetic valve angulation relative to the right ventricular outflow tract was associated with structural valve deterioration and was closely related to valve oversizing. Valve-outflow tract geometry, rather than valve size alone, may influence valve durability.

Topics

Humans; Pulmonary Valve; Heart Valve Prosthesis; Retrospective Studies; Female; Heart Valve Prosthesis Implantation; Bioprosthesis; Prosthesis Failure; Pulmonary Valve Insufficiency; Male; Tomography, X-Ray Computed; Heart Defects, Congenital

DOI: 10.1016/j.athoracsur.2026.05.036 · PubMed: 42250585

Spotted a mistake? Suggest a correction

More in Cardiothoracic & Vascular Surgery

Ann Thorac Surg · Nov 20, 2026 · Research · Pediatric · Cardiothoracic & Vascular Surgery

One-year survival improved in hybrid stage 1 single ventricle palliation over time

J Vasc Surg · Nov 16, 2026 · Research · Cardiothoracic & Vascular Surgery

Seven point five percent of patients developed vascular graft infection after bloodstream infection

J Vasc Surg · Nov 14, 2026 · Research · Cardiothoracic & Vascular Surgery

Fenestrated Endografts Provide Superior Outcomes Compared to Branched Devices in Juxtarenal Aortic Repair

Eur J Vasc Endovasc Surg · Nov 13, 2026 · Meta-analysis · Cardiothoracic & Vascular Surgery

Dual antiplatelet therapy showed no clear benefit after endovascular aortic repair

J Thorac Cardiovasc Surg · Nov 12, 2026 · Research · Cardiothoracic & Vascular Surgery

Early surgery did not increase hemorrhagic transformation in infective endocarditis patients