Imaging accuracy for Crohn's disease strictures is similar across ultrasound, MRI, and CT scans
Variability and performance of radiologic stricture parameters in Crohn's disease: a systematic review and meta-analysis
Clinical question: What is the diagnostic performance of imaging parameters for Crohn's disease strictures?
Why it matters: Definitions of strictures in Crohn's disease remain variable and non-standardised across different cross-sectional imaging methods.
- Researchers analyzed 30 studies involving 1866 patients to evaluate how ultrasound, magnetic resonance imaging, and computed tomography detect Crohn's disease strictures.
- The pooled sensitivity for ultrasound was 0.88, magnetic resonance enterography was 0.82, and computed tomography enterography was 0.83, with no statistically significant difference between modalities.
- Luminal narrowing, bowel wall thickening, and pre-stenotic dilation were the most common descriptors used to define strictures in the included studies.
Limitation the authors note: Variations in histological criteria and limited evidence for some modalities may limit generalizability.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Cite this article
Dal Buono A, Faita F, Bencardino S, Maiucci G, Barchi A, Armuzzi A. Variability and performance of radiologic stricture parameters in Crohn's disease: a systematic review and meta-analysis. eClinicalMedicine. 2025. doi:10.1016/j.eclinm.2025.103541
Spotted a mistake? Suggest a correction