VasSurDetect: An AI-based Chatbot for Rapid, Photo-based Feedback in Microsurgical Suturing Training
Abstract
Background
Microsurgical suturing training requires precise, repeated feedback, but faculty feedback is often delayed, subjective, and limited by availability. We developed VasSurDetect, a LINE mobile messaging application (LY Corporation, Tokyo, Japan)-based artificial intelligence chatbot, to provide rapid photo-based feedback on vascular suturing end-product quality. Methods
A total of 350 paired microscope images from simulation-based chicken wing vessel practice were collected as inside and outside views. Knots, purchase segments, and leftover suture material were annotated. Nine object detection models were trained and compared. Bounding-box outputs were converted into quantitative metrics for stitch number, purchase length, interstitch distance, stitch angle, stitch axis, and leftover suture length. The selected model was deployed in a chatbot workflow that accepts 2 microscope photographs and returns an automated report. Results
For inside-view detection, YOLOv10 achieved the highest overall performance, with an F1 score of approximately 0.89. For outside-view detection, YOLOv8 and YOLOv10 performed comparably, each achieving an F1 score of approximately 0.55. YOLOv10 was selected for system deployment. The implemented workflow generated stitch-level measurements, including stitch spacing, angular alignment, and leftover suture length, with a mean spacing error of approximately 0.4 mm and an angular alignment error of approximately 10 degrees. Automated feedback was delivered within 10 seconds. Conclusions
VasSurDetect provides rapid, standardized, image-based feedback for microsurgical suturing practice without additional hardware. It is intended to complement, not replace, expert supervision by supporting high-frequency deliberate practice and objective performance tracking in simulation-based microsurgical training.
Spotted a mistake? Suggest a correction
More in Plastic & Reconstructive Surgery
Releasable plating systems had higher complication rates than continuous systems
Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes
Saphenous nerve terminated near navicular cuneiform joint in 45% of specimens
Evaluating Saphenous Nerve Variations With Classification System in the Lower Limb, an Anatomical Study With Surgical Relevance
Evaluation of an Animated Patient Information Video: Improving Consent and Decision-making for Deep Inferior Epigastric Perforator Flap Breast Reconstruction
Most plastic surgery residents satisfied with elective rotation experience
Optimizing the Chief Resident Elective Rotation: Insights From Alumni Feedback in Plastic Surgery Training