Visual abstractsVisuals
ResearchInvestigative Ophthalmology & Visual Science · Sep 1, 2026

Visual Acuity: Comparison of ETDRS Charts Using Latin Letters, Tumbling E, or Landolt C Optotypes

Kalloniatis M, Wang H, Meier K, Patel NB, Phu J
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose Visual acuity (VA) is a key outcome measure in clinical practice, epidemiological studies, and in clinical trials. However, letter-based charts may disadvantage individuals who are illiterate or are unfamiliar with Latin text, thereby limiting subject participation and complicating comparisons across studies. We compared VA using Early Treatment Diabetic Retinopathy Study (ETDRS) charts for Latin letters, Landolt-C, or Tumbling-E optotypes to determine their association and measurement variability. Methods Seventy-eight patients from an eye clinic underwent VA testing using the various optotypes on an ETDRS logMAR chart. VA was measured with a pinhole (PH), uncorrected, and corrected for the three optotypes, and compared with results in severe VA loss. Regression slopes, coefficients of determination, and limits of agreement (LoA) were determined. Results All three optotype VAs showed a similar response to PH use, with an average improvement of approximately three logMAR lines. For uncorrected VA, Tumbling-E and Landolt-C showed slopes near 1.0 relative to letter VA across a broad range with R2 > 0.93. For corrected VA, slopes were 0.73 (Tumbling-E) and 0.58 (Landolt-C), with R2 ≈0.70. Combining our data with prior studies extended the range to 20/2000 for Landolt C and letter VA, yielding slopes near 1.0 and R2 > 0.94. LoA across comparisons ranged from logMAR ±0.12 to ±0.23. Conclusions Non-letter optotypes provide clinically useful and broadly comparable measures of VA at the population level supporting their use in clinical practice or population/clinical studies. However, the wide variability means they cannot be considered interchangeable for individual subjects.

Topics

Humans; Visual Acuity; Vision Tests; Female; Male; Aged; Middle Aged; Reproducibility of Results; Aged, 80 and over

DOI: 10.1167/iovs.67.11.4 · PubMed: 42678222

Cite this article

Kalloniatis M, Wang H, Meier K, Patel NB, Phu J. Visual Acuity: Comparison of ETDRS Charts Using Latin Letters, Tumbling E, or Landolt C Optotypes. Invest Ophthalmol Vis Sci. 2026. doi:10.1167/iovs.67.11.4

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Invest Ophthalmol Vis Sci · Feb 19, 2026 · Research · Pediatric · Ophthalmology

Contrast Sensitivity and Low-Contrast Visual Acuity in Children With Low Vision

Invest Ophthalmol Vis Sci · Jul 6, 2026 · Research · Pediatric · Ophthalmology

Psychometric Performance of Children With Amblyopia During a Tablet-Based Adaptive Visual Acuity Assessment

JAMA Ophthalmol · Aug 27, 2026 · Research · Pediatric · Ophthalmology

HOTV Vision Test Compared With Tumbling E for Pediatric Vision Screening

Invest Ophthalmol Vis Sci · Jan 28, 2026 · Research · Ophthalmology

Preserved Contrast Sensitivity in Early and Intermediate Age-Related Macular Degeneration and Marked Loss in Late Stage: ALSTAR2

NEJM · Oct 20, 2025 · Clinical trial · Ophthalmology

Subretinal Photovoltaic Implant to Restore Vision in Geographic Atrophy Due to AMD