Visual abstractsVisuals
ResearchOphthalmology Science · Mar 12, 2026

Volumetric Analysis of Perimetry Tests to Guide Central Testing: The Functional Vulnerability Zone

Phu J, Wang H, Kalloniatis M
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose To use volumetric analysis applied to total deviation (TD) perimetric data to characterize the presence of residual sensitivity measurable using the 10-2 in lieu of the 24-2 test grid in glaucoma (the functional vulnerability zone [FVZ]) and develop a prototype end-user application for clinical guidance. Design Cross-sectional study. Subjects Six hundred twenty-six pairs of Humphrey Field Analyzer 10-2 Swedish Interactive Thresholding Algorithm (SITA)-Fast and 24-2 SITA-Faster test results of 160 subjects. Methods Total deviation values located within 10° from fixation (10-2, 68 locations; 24-2, 12 locations) were extracted. Volumetric analysis was performed to calculate the difference in TD "volume" (10-2 - 24-2) for each pair of results. Then, 24-2 test locations were interpolated across the central 10° to obtain "equivalent" 10-2 test locations used to calculate number of test locations gained (10-2 - 24-2). A positive TD volume difference and positive gain represented the presence of an FVZ. Linear regression and principal components analysis were used to identify 24-2 test features that may predict the presence of an FVZ. Main outcome measures Volumetric differences in visual field TD as a surrogate for a FVZ. Results Visual field global indices and the number of central 24-2 defects predicted TD volume difference (P < 0.0001), with 24-2 mean deviation (MD) showing the highest R 2 (0.32). All parameters had low R 2 values when predicting gain. A simplified model comprising 24-2 MD and number of central 24-2 TD probability (TDP) defects (P < 0.01) provided a method for clinically identifying the likelihood of an FVZ. Principal components analysis revealed 2 principal components (24-2 global indices and pointwise probability scores) that accounted for 79.7% of the variance, with principal component 1 accounting for 69.3% and comprising 24-2 MD and number of central 24-2 TDP scores at P < 2%. Conclusions The FVZ offers a data-driven approach to identifying residual dynamic range using the 10-2 test grid. A prototype model for predicting the likelihood of 10-2 utility in progression analysis is proposed. Financial disclosures The authors have no proprietary or commercial interest in any materials discussed in this article.

DOI: 10.1016/j.xops.2026.101152 · PubMed: 42064013

Cite this article

Phu J, Wang H, Kalloniatis M. Volumetric Analysis of Perimetry Tests to Guide Central Testing: The Functional Vulnerability Zone. Ophthalmol Sci. 2026. doi:10.1016/j.xops.2026.101152

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Ophthalmology

Am J Ophthalmol · Nov 20, 2026 · Research · Pediatric · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

JAMA Ophthalmol · Nov 19, 2026 · Randomized trial · Pediatric · Ophthalmology Visual abstract

Higher concentration atropine eye drops slowed myopia progression in children

Am J Ophthalmol · Nov 19, 2026 · Research · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Ophthalmology · Nov 18, 2026 · Research · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Am J Ophthalmol · Nov 18, 2026 · Research · Ophthalmology

Static perimetry thresholds developed to assess visual field loss severity in retinitis pigmentosa patients