Smaller 27-gauge needles yielded more diagnostic thyroid biopsy samples than 25-gauge needles
A Blinded Randomized Trial Comparing 2 Needle Gauges for Fine-Needle Biopsy of Thyroid Nodules
Prospective blinded randomized trialBenefit found
Are 25-gauge or 27-gauge needles better for thyroid nodule fine-needle biopsy?
Who
148
107 patients with 148 thyroid nodules · Thyroid clinic in otolaryngology practice in a community
Compared
25-gauge needles: 25% (19/77) nondiagnostic cytology
27-gauge needles: 11% (8/70) nondiagnostic cytology
Main outcome
nondiagnostic cytology rate and patient pain
Result: 95% CI, 1.47%-25.97%
Bottom line: The 27-gauge needle yields better diagnostic information and lower nondiagnostic rates than the 25-gauge needle.
OTO Open · 2021-05-10Download image
Clinical question: Are 25-gauge or 27-gauge needles better for thyroid nodule fine-needle biopsy?
Key points
- Researchers conducted a blinded randomized trial on 148 thyroid nodules in 107 patients to compare 25-gauge and 27-gauge needles.
- Nondiagnostic results occurred in 25% (19/77) of 25-gauge needle samples compared to 11% (8/70) of 27-gauge needle samples.
- Samples from 25-gauge needles had a higher average blood and fibrin artifact score, but there were no differences in patient pain.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Shumrick CM, Simmonds JC, Ogden LL, Snowden CA, Dhingra JK. A Blinded Randomized Trial Comparing 2 Needle Gauges for Fine-Needle Biopsy of Thyroid Nodules. OTO Open. 2021. doi:10.1177/2473974X211013732
Spotted a mistake? Suggest a correction