← Back to the study · · Download slide

Journal club handout · OTO Open · 2021-05-10

A Blinded Randomized Trial Comparing 2 Needle Gauges for Fine-Needle Biopsy of Thyroid Nodules

Key result: Smaller 27-gauge needles yielded more diagnostic thyroid biopsy samples than 25-gauge needles

Prospective blinded randomized trialBenefit found
Are 25-gauge or 27-gauge needles better for thyroid nodule fine-needle biopsy?
Who
148
107 patients with 148 thyroid nodules · Thyroid clinic in otolaryngology practice in a community
Compared
25-gauge needles: 25% (19/77) nondiagnostic cytology
27-gauge needles: 11% (8/70) nondiagnostic cytology
Main outcome
nondiagnostic cytology rate and patient pain
Result: 95% CI, 1.47%-25.97%
Bottom line: The 27-gauge needle yields better diagnostic information and lower nondiagnostic rates than the 25-gauge needle.
OTO Open · 2021-05-10Download image

Key points

Discussion prompts

  1. Would these patients look like yours? Who was left out?
  2. Is the main outcome one that matters to patients?
  3. Is the difference large enough to change what you do?

Cite: Shumrick CM, Simmonds JC, Ogden LL, Snowden CA, Dhingra JK. A Blinded Randomized Trial Comparing 2 Needle Gauges for Fine-Needle Biopsy of Thyroid Nodules. OTO Open. 2021. doi:10.1177/2473974X211013732

Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/a-blinded-randomized-trial-comparing-2-needle-gauges-for-fine-needle-1fpcig9/ (AI-assisted from the abstract; check the paper before relying on it).