Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Nov 24, 2025

A multi-dynamic low-rank deep image prior for three-dimensional real-time cardiovascular magnetic resonance imaging

Chen C, Vornehm M, Bu Z, Chandrasekaran P, Sultan MA, Arshad SM, et al
Radiology & ImagingCardiologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Purpose To develop a reconstruction framework for three-dimensional (3D) real-time cine cardiovascular magnetic resonance (CMR) from highly undersampled data without requiring fully sampled training datasets. Methods We developed a multi-dynamic low-rank deep image prior (ML-DIP) framework that models spatial image content and deformation fields using separate neural networks. These sub-networks are jointly trained per scan to reconstruct the dynamic image series directly from undersampled k-space data. ML-DIP was evaluated on (i) a 3D cine digital phantom with simulated premature ventricular contractions (PVCs), (ii) 10 healthy subjects (including 2 scanned during both rest and exercise), and (iii) 12 patients with a history of PVCs. Phantom results were assessed using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). In vivo performance was evaluated by comparing left-ventricular function quantification (against two-dimensional [2D] real-time cine) and image quality (against 2D real-time cine and binning-based five-dimensional cine [5D-Cine]). Results In the phantom study, ML-DIP achieved PSNR >29 dB and SSIM >0.90 for scan times as short as 2min, while recovering cardiac motion, respiratory motion, and PVC events. In healthy subjects, ML-DIP yielded functional measurements comparable to 2D cine and higher image quality than 5D-Cine, including during exercise with high heart rates and bulk motion. In PVC patients, ML-DIP preserved beat-to-beat variations and reconstructed irregular beats, whereas 5D-Cine showed motion artifacts and information loss due to binning. Conclusion ML-DIP enables high-quality 3D real-time CMR with acceleration factors exceeding 1000 by learning low-rank spatial and motion representations from undersampled data, without relying on external fully sampled training datasets.

Topics

Humans; Magnetic Resonance Imaging, Cine; Predictive Value of Tests; Image Interpretation, Computer-Assisted; Ventricular Function, Left; Imaging, Three-Dimensional; Female; Phantoms, Imaging; Ventricular Premature Complexes; Male; Reproducibility of Results; Adult

DOI: 10.1016/j.jocmr.2025.102015 · PubMed: 41297766

Cite this article

Chen C, Vornehm M, Bu Z, Chandrasekaran P, Sultan MA, Arshad SM. A multi-dynamic low-rank deep image prior for three-dimensional real-time cardiovascular magnetic resonance imaging. J Cardiovasc Magn Reson. 2025. doi:10.1016/j.jocmr.2025.102015

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

J Cardiovasc Magn Reson · Jan 23, 2026 · Research · Radiology & Imaging

Isotropic three-dimensional cardiac cine imaging at 0.55T using stack-of-spiral sampling and four-dimensional iterative motion compensation

J Cardiovasc Magn Reson · Dec 24, 2025 · Research · Radiology & Imaging, Cardiology

Free-breathing three-dimensional whole-heart adiabatic T1ρ mapping for non-contrast tissue characterization at 0.55T

J Cardiovasc Magn Reson · Nov 25, 2025 · Research · Radiology & Imaging, Cardiology

Precision, prognosis, and clinical performance of rounded and trabecular segmentation of cine cardiovascular magnetic resonance

J Cardiovasc Magn Reson · Feb 17, 2026 · Research · Basic science · Radiology & Imaging, Digital Health & AI

Open-source pre-clinical image segmentation: mouse cardiac magnetic resonance imaging datasets with a deep learning segmentation framework

J Cardiovasc Magn Reson · Dec 24, 2025 · Research · Radiology & Imaging, Cardiology

Cardiac function assessment with deep-learning-based automatic segmentation of free-running four-dimensional whole-heart cardiovascular magnetic resonance