ResearchEuropean Radiology · Mar 6, 2026
A personalized iodine delivery rate-based injection protocol in coronary angiography on photon-counting CT
Busselot T, Giordano P, Sneyers V, Coudyzer W, Torfs K, Adriaenssens T, et al
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Objectives
To propose and validate a personalized iodine delivery rate (IDR) based injection protocol for coronary CT angiography (cCTA) on photon-counting CT. Materials and methods
First, ideal IDR (IDRIDEAL) was retrospectively calculated for a HU target of 500 in 55 keV image reconstructions. Next, linear regression analysis was performed with IDRIDEAL and demographic parameters to derive a candidate IDR formula. This was implemented in two validation groups characterized by injection rate (3.5 and 5.0 mL/s). Here, coronary enhancement was quantified and equivalence assessed for a predefined HU range (500 ± 50). Additionally, a reader study assessed perceived enhancement of the coronary tree. Results
This IRB-approved study used a retrospective cohort of 162 patients (group A: 58 ± 12 years; 81 men) and two prospective cohorts of 51 patients (group B1: 60 ± 13 years; 22 men and group B2: 59 ± 12 years; 30 men). IDRIDEAL correlated best with fat-free mass (FFM) (r = 0.67) and was integrated for contrast personalization. Prospectively, mean coronary enhancement was 533 ± 97 HU and 528 ± 68 HU for both groups (p = 0.79) with mean IDR values of 1.01 ± 0.11 gI/s and 1.07 ± 0.14 gI/s. However, distribution variances were significantly different (p = 0.015). Subjective scoring showed no differences between the two groups on overall and per-vessel level (p > 0.05). Conclusion
A personalized, IDR-based injection protocol for cCTA was proposed and validated. FFM was best for IDRIDEAL prediction. Higher injection rates provided more precise coronary enhancement. Key points
Question Virtual mono-energetic images lead to low iodine delivery rate settings, but the impact on coronary enhancement is not clear. Findings An iodine delivery rate-based injection protocol implementing personalized contrast volume dilutions with set injection duration and high injection rate improved coronary enhancement. Clinical relevance Iodine delivery rate fine-tuning is a promising approach for coronary CT angiography with low iodine volumes. High injection rates provide more accurate and precise coronary enhancement.
Topics
Coronary Angiography; Computed Tomography Angiography; Retrospective Studies; Humans; Male; Female; Middle Aged; Aged; Contrast Media; Coronary Artery Disease; Prospective Studies; Iohexol
DOI: 10.1007/s00330-026-12413-x · PubMed: 41792575
Spotted a mistake? Suggest a correction
More in Radiology & Imaging
ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging
Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment
ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging
Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
Classic signs in head and neck imaging-a quick guide for the radiology resident
ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging
Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease