Closed-loop insulin delivery was associated with less hypoglycemia in postpartum individuals with type 1 diabetes
A Randomized Trial of Closed-Loop Insulin Delivery Postpartum in Type 1 Diabetes
Clinical question: Is closed-loop insulin delivery effective postpartum in type 1 diabetes?
Why it matters: It was unknown if hybrid closed-loop insulin delivery systems, which automatically adjust insulin based on sensor readings, are effective for managing blood sugar after childbirth.
- Eighteen participants with type 1 diabetes were randomized to either hybrid closed-loop insulin delivery or sensor-augmented pump therapy for 12 weeks postpartum.
- The closed-loop group spent less time with blood glucose <70 mg/dL (1.7 ± 0.8% vs. 5.5 ± 3.3%) and <54 mg/dL (0.3 ± 0.2% vs. 1.1 ± 0.9%).
- There were no episodes of diabetic ketoacidosis or severe hypoglycemia in either group during the randomized or continuation phases.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Topics
Cite this article
Donovan LE, Feig DS, Lemieux P, Murphy HR, Bell RC, Sigal RJ. A Randomized Trial of Closed-Loop Insulin Delivery Postpartum in Type 1 Diabetes. Diabetes Care. 2023. doi:10.2337/dc23-0882