Fractional exhaled nitric oxide shows good accuracy for diagnosing asthma in adults and children
Accuracy of type 2 inflammatory biomarkers to diagnose asthma in adults and children: a meta-analysis of 30 studies with prospective validation in an adult primary care cohort
Roy MA, Gronnier M, Désy L, Pouliot L, Lemaire-Paquette S, Lemieux SÈ, et al
Why it matters: Diagnosing asthma is difficult because many patients have low bronchodilator reversibility or limited access to bronchial provocation tests.
Key points
Researchers analyzed 30 studies involving 7,141 adults and 989 children to evaluate biomarkers for asthma diagnosis.
Fractional exhaled nitric oxide, a measure of airway inflammation, had an area under the curve of 0.80 in adults and 0.75 in children.
Blood eosinophil count, a measure of specific white blood cells, showed weak accuracy and added no value when combined with fractional exhaled nitric oxide.
Limitation the authors note: The authors noted that fractional exhaled nitric oxide diagnostic accuracy declined within 2 weeks of inhaled corticosteroid exposure.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Background
Asthma diagnosis is challenging, partly due to low yield of bronchodilator reversibility and limited access to bronchial provocation tests (BPTs). Fractional exhaled nitric oxide (FeNO) and blood eosinophil count (BEC) have been proposed as rule-in biomarkers. We aimed to evaluate the diagnostic accuracy of these biomarkers in adults and children, focusing on primary care applicability. Methods
In this systematic review and meta-analysis, we searched MEDLINEand other databases from inception to June 4, 2024, for eligible diagnostic studies (randomised trials, cohort, cross-sectional, case-control, or case series). We included studies comparing FeNO or BEC with BPT or bronchodilator reversibility plus BPT in patients aged 5 years or older with suspected asthma and normal spirometry. Diagnostic performance in adults (aged ≥18 years) and children (aged 5-17 years) was estimated by the primary outcome measure of area under the receiver operating characteristic curve (AUC). Rule-in thresholds (prespecified) and rule-out thresholds (post hoc) were derived. In a single-centre cohort study (DIVE), analyses were prospectively replicated in bronchodilator reversibility-negative individuals referred for a BPT by primary care. Patients underwent FeNO and BEC immediately before a standardised methacholine BPT. The primary outcome for DIVE was biomarker performance for positive BPT, ascertained by AUC for FeNO, BEC, and the combination of FeNO and BEC. Post-hoc analyses addressed potential confounding by inhaled corticosteroid exposure. The systematic review and meta-analysis was registered with PROSPERO (CRD42023489738). The DIVE study was registered with ClinicalTrials.gov (NCT05592519). Findings
22 adult studies with 7141 patients and nine paediatric studies with 989 patients were included for meta-analysis (30 studies overall, with one study in both adults and children). FeNO diagnostic accuracy was good in adults (AUC 0·80 [95% CI 0·73-0·85]) and fair in children (0·75 [0·65-0·82]). In adults, FeNO of 48 ppb or higher achieved a positive likelihood ratio of 10·1 (95% CI 8·9-11·2). At a 20% prevalence reflecting primary care, a FeNO of 65 ppb or higher achieved a positive predictive value (PPV) of 80% (95% CI 72-86), and FeNO of less than 20 ppb achieved a negative predictive value of 93% (91-94) with 18% (12-25) missed diagnoses. In children, at the 56% aggregated study prevalence, FeNO of 30 ppb or higher achieved a PPV of 80% (95% CI 73-84). In adults, BEC showed weak stand-alone accuracy (AUC 0·65 [95% CI 0·59-0·71]) and added no value to FeNO. The DIVE cohort study (22 [18%] of 123 patients BPT positive) validated results of the meta-analysis in adults, with similar AUCs (0·77 [95% CI 0·65-0·89] for FeNO alone and 0·67 [0·53-0·80] for BEC alone). FeNO thresholds correctly classifyied rule-in decisions (FeNO >65 ppb: PPV 73% [95% CI 39-94]) and rule-out decisions (FeNO <20 ppb: NPV 92% [82-97]) with 89% overall accuracy. In both the meta-analysis and the DIVE cohort, FeNO diagnostic accuracy declined within 2 weeks of inhaled corticosteroid exposure. Interpretation
In adults and children with suspected asthma, FeNO predicted airway hyper-responsiveness and enabled clinically applicable rule-in and rule-out thresholds. BEC performed poorly alone and added no value to FeNO. Findings and thresholds were replicated in a prospective adult primary care cohort; a similar study in children is ongoing. FeNO-guided diagnostic algorithms using context-specific rule-in and rule-out thresholds, while accounting for recent inhaled corticosteroid exposure, warrant consideration. Funding