ResearchJournal of the American College of Cardiology · Apr 29, 2026

Aligning Coronary Stent Trial Enrollment With the U.S. Intended-Use Population: Implications of Site Selection

Batchelor WB, Califf R, Mehran R, Stone G, Blumer V, O'Connor C, et al
CardiologyAdult
Read the full paper free at the publisher ↗

Abstract

Background Class III cardiovascular device premarket approval (PMA) studies often fail to fully represent the intended-use population (IUP) owing to low enrollment of racial and ethnic minority subjects and women. The impact of research site selection on this is unknown. Objectives In this study, we sought to determine if site characteristics predict enrollment of demographic minority and female participants in coronary stent PMA trials and evaluate if site selection could improve representation of the IUP. Methods We pooled data from 8,859 U.S. participants enrolled in 9 pivotal coronary stent PMA studies (2003-2018) across 196 sites. Site characteristics included U.S. region, surrounding county demographics, teaching status, Veterans Administration affiliation, trial volume, female principal investigator (PI) involvement, and number of acute hospital beds. Multivariable regression identified predictors of minority and female enrollment. Participant-to-prevalence ratios (PPRs) were modeled under varying site selection scenarios. Results Minority participants (12%; PPR = 0.48) and women (30%; PPR = 0.77) were underrepresented. Minority enrollment varied markedly across sites and was predicted by West and South regions, county minority population, population density, and per-capita income (R2 = 0.50; P < 0.001). Modeling estimated that reallocating enrollment from low to high minority-enrolling sites could normalize Black and Hispanic representation (PPRs ≥0.80) without compromising that of non-Hispanic Whites (PPR = 1.00). Female enrollment showed less variation and was poorly predicted by research site characteristics and site PI gender (non-VA status only; R2 = 0.095; P < 0.001); however there were few female PIs (<6%), limiting correlation. Conclusions Coronary stent PMA studies do not fully reflect the IUP, owing to marked underrepresentation of minority participants and modest underrepresentation of women. Because minority enrollment is influenced by site characteristics, targeted site selection could improve representation; however, improving female enrollment requires alternative strategies. These insights have implications on the planning and design of future cardiovascular device trials.

Subject terms

Humans; Female; United States; Patient Selection; Stents; Minority Groups; White; Coronary Artery Disease

DOI: 10.1016/j.jacc.2026.01.088 · PubMed: 42053200

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Batchelor WB, Califf R, Mehran R, et al. Aligning Coronary Stent Trial Enrollment With the U.S. Intended-Use Population: Implications of Site Selection. J Am Coll Cardiol. 2026;87(16):2163-2176. doi:10.1016/j.jacc.2026.01.088

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Systematic review · J Vasc Surg · Dec 27, 2023 · Cardiothoracic & Vascular Surgery, Cardiology

Guidelines recommend carotid intervention for patients with asymptomatic stenosis of 70% or more

Guideline · Eur J Vasc Endovasc Surg · May 21, 2025 · Cardiothoracic & Vascular Surgery, Cardiology

European experts agree on guidelines for endovascular repair of ascending aorta diseases

Randomized trial n = 773 · Eur Heart J · Nov 19, 2025 · Cardiology

Achieving stent optimization via optical coherence tomography was associated with better clinical outcomes in complex lesions

Guideline · Eur Heart J · May 15, 2026 · Cardiology

European experts agree intracoronary imaging guides left main heart stenting

Randomized trial n = 784 · JACC · Oct 28, 2024 · Cardiology

Drug-coated balloons for side branches lowered major adverse cardiac events in coronary bifurcation stenting