High-flow nasal oxygen was associated with lower desaturation risk than facemask in morbidly obese patients
Apnoeic oxygenation in morbid obesity: a randomised controlled trial comparing facemask and high-flow nasal oxygen delivery
Why it matters: The effectiveness of high-flow nasal oxygen compared to low-flow facemask oxygen for maintaining oxygen levels during periods of not breathing is uncertain in the obese population.
- Eighty morbidly obese patients undergoing bariatric surgery were randomly assigned to receive either high-flow nasal oxygen at 70 L min-1 or facemask oxygen at 15 L min-1.
- The risk of oxygen saturation dropping to 92% or below was significantly lower in the high-flow nasal oxygen group (hazard ratio=0.27; 95% confidence interval [CI], 0.11-0.65; P=0.007).
- The median time without breathing during anesthesia was 18 min in both the high-flow nasal oxygen group (IQR 18-18 min) and the facemask group (IQR 4.1-18 min).
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Schutzer-Weissmann J, Wojcikiewicz T, Karmali A, Lukosiute A, Sun R, Kanji R. Apnoeic oxygenation in morbid obesity: a randomised controlled trial comparing facemask and high-flow nasal oxygen delivery. Br J Anaesth. 2022. doi:10.1016/j.bja.2021.12.011
Spotted a mistake? Suggest a correction
The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.