Randomized trialAnaesthesia · Dec 22, 2020

Evaluating the ventilatory effect of transnasal humidified rapid insufflation ventilatory exchange in apnoeic small children with two different oxygen flow rates: a randomised controlled trial

Riva T, Préel N, Theiler L, Greif R, Bütikofer L, Ulmer F, et al
AnesthesiologyPediatricsPulmonologyPediatric
Read the full paper free at the publisher ↗
Top Anesthesiology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Abstract

Transnasal humidified rapid insufflation ventilatory exchange prolongs safe apnoeic oxygenation time in children. In adults, transnasal humidified rapid insufflation ventilatory exchange is reported to have a ventilatory effect with PaCO2 levels increasing less rapidly than without it. This ventilatory effect has yet to be reproduced in children. In this non-inferiority study, we tested the hypothesis that children weighing 10-15 kg exhibit no difference in carbon dioxide clearance when comparing two different high-flow nasal therapy flow rates during a 10-min apnoea period. Following standardised induction of anaesthesia including neuromuscular blockade, patients were randomly allocated to high-flow nasal therapy of 100% oxygen at 2 or 4 l.kg-1 .min-1 . Airway patency was ensured by continuous jaw thrust. The study intervention was terminated for safety reasons when SpO2 values dropped < 95%, or transcutaneous carbon dioxide levels rose > 9.3 kPa, or near-infrared spectroscopy values dropped > 20% from their baseline values, or after an apnoeic period of 10 min. Fifteen patients were included in each group. In the 2 l.kg-1 .min-1 group, mean (SD) transcutaneous carbon dioxide increase was 0.46 (0.11) kPa.min-1 , while in the 4 l.kg-1 .min-1 group it was 0.46 (0.12) kPa.min-1 . The upper limit of a one-sided 95%CI for the difference between groups was 0.07 kPa.min-1 , lower than the predefined non-inferiority margin of 0.147 kPa.min-1 (p = 0.001). The lower flow rate of 2 l.kg-1 .min-1 was non-inferior to 4 l.kg-1 .min-1 relative to the transcutaneous carbon dioxide increase. In conclusion, an additional ventilatory effect of either 2 or 4 l.kg-1 .min-1 high-flow nasal therapy in apnoeic children weighing 10-15 kg appears to be absent.

Subject terms

Administration, Intranasal; Apnea; Child, Preschool; Female; Humans; Infant; Insufflation; Male; Oxygen; Oxygen Inhalation Therapy; Prospective Studies; Pulmonary Ventilation

DOI: 10.1111/anae.15335 · PubMed: 33351194

Cite this article

Riva T, Préel N, Theiler L, et al. Evaluating the ventilatory effect of transnasal humidified rapid insufflation ventilatory exchange in apnoeic small children with two different oxygen flow rates: a randomised controlled trial. Anaesthesia. 2020. doi:10.1111/anae.15335

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Randomized trial · Br J Anaesth · Dec 8, 2021 · Anesthesiology, Surgery

High flow oxygen delivery was associated with longer safe apnea times in paralyzed obese patients

Randomized trial · Br J Anaesth · Jan 11, 2022 · Anesthesiology, Endocrinology & Diabetes

High-flow nasal oxygen was associated with lower desaturation risk than facemask in morbidly obese patients

Randomized trial · Anaesthesia · Dec 15, 2023 · Anesthesiology

High-flow nasal oxygen rates did not significantly change carbon dioxide levels during apnea

Randomized trial · Anaesthesia · Jun 28, 2021 · Anesthesiology

High-flow nasal oxygen did not reduce hypoxaemia compared to low-flow nasal and mouthguard oxygen

Randomized trial · Anaesthesia · Feb 18, 2021 · Anesthesiology

High-flow nasal oxygen worked as well as facemask for pre-oxygenation in emergency surgery