Visual abstractsVisuals
ResearchEuropean Radiology · Mar 5, 2026

Artificial intelligence-based coronary computed tomography angiography quantification of atherosclerosis burden: comparison with intravascular ultrasound in the INVICTUS Registry

Nakanishi R, Okubo R, Matsuo H, Sobue Y, Kaneko U, Sato H, et al
Radiology & ImagingAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objectives Automated artificial intelligence (AI)-based assessment of atherosclerosis burden applied to coronary computed tomography angiography (CCTA) can optimize image processing times, standardize interpretation, and minimize inter-observer variability. We investigated the diagnostic utility of AI-based CCTA quantification (AI-QCT) of coronary atherosclerosis in coronary segments co-registered with intravascular ultrasound (IVUS) of diseased and non-diseased segments. Materials and methods Patients who underwent CCTA and IVUS in the INVICTUS registry (ClinicalTrials.gov: NCT04066062) were enrolled. Images were analyzed by independent core laboratories blinded to each modality's findings. Vessel external elastic membrane (EEM), lumen, plaque volumes, plaque burden, and percent atheroma volume (PAV) were quantified in whole co-registered segments and subsegments containing non-calcified and low-attenuation plaques. A calcium index was calculated for the whole co-registered segment. Results A total of 108 vessels from 85 patients were included. Pearson's correlation demonstrated strong associations between AI-QCT and IVUS in quantifying the EEM volume (r = 0.899), lumen volume (r = 0.943), and plaque volume (r = 0.833), length-normalized PAV (r = 0.851), and calcium index (r = 0.960) in the whole-segment analysis. Strong correlations were seen for vessel, lumen, and plaque volumes in non-calcified (Pearson's coefficient: 0.95, 0.97, and 0.83, respectively) and low-attenuation (Pearson's coefficient: 0.90, 0.86, and 0.86, respectively) plaque segments. The minimum lumen area was 0.61 ± 1.18 mm2 (95% CI, -0.83 to -0.38) smaller by AI-QCT than IVUS, with a similar lumen area stenosis (mean difference, 1.26 ± 24.17; 95% CI, -3.37 to 5.90). Conclusions AI-QCT quantification of atherosclerosis burden showed high correlations and close agreement with IVUS in whole-segment and segments with non-calcified and low-attenuation plaques. Key points Question Coronary atheroma burden is a powerful predictor of cardiovascular events. Can AI-based coronary CT angiography (CCTA) accurately quantify atherosclerotic burden across the full disease spectrum when compared with intravascular ultrasound (IVUS)? Findings AI-based CCTA quantification (AI-QCT) showed strong correlations with IVUS for plaque volume, burden, and calcium across whole coronary segments, including non-calcified and low-attenuation plaques. Clinical relevance AI-QCT provides rapid, automatic, and accurate atherosclerosis quantification without reader-dependent variability, enabling standardized cardiovascular risk assessment, treatment monitoring, and therapeutic decision-making across all disease severity spectrum in routine clinical practice.

Topics

Aged; Female; Humans; Male; Middle Aged; Artificial Intelligence; Atherosclerosis; Computed Tomography Angiography; Coronary Artery Disease; Intelligent Systems; Plaque, Atherosclerotic; Registries

DOI: 10.1007/s00330-026-12412-y · PubMed: 41781729 · Registered: NCT04066062

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease