ResearchEuropean Radiology Experimental · Sep 10, 2026

Assessment of emphysema with simulated low-dose dark-field radiography

Bast H, Schick RC, Koehler T, Gassert FT, Marka AW, Sauter AP, et al
Radiology & ImagingAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objective Dark-field radiography allows the visualization of lung tissue changes associated with pulmonary emphysema. Simulations were used to investigate the impact of radiation dose reduction on the diagnostic accuracy of emphysema detection. Materials and methods Dark-field and attenuation chest radiographs acquired during an ongoing clinical study were used to simulate multiple low-dose counterparts corresponding to median effective doses between 7 and 18 µSv. All study participants had undergone a medically indicated chest computed tomography scan that showed either pulmonary emphysema or no lung pathologies. In a randomized reader study, three radiologists independently assessed the simulated low-dose dark-field and attenuation radiographs as well as the original images for the presence of emphysema. The area under the curves (AUC) of the receiver operating characteristics (ROC) were analyzed using Obuchowski's method. ROC curves were also generated by using different values of the dark-field coefficient to differentiate between absent and at least mild emphysema. Results The original (full-dose) images and simulated low-dose images of 93 participants (57 males, 36 females) were included, with participants' median age of 66 years (interquartile range 54 to 73 years). The radiologists' ROC curves of the simulated low-dose images at 11 µSv (AUC = 0.84) did not differ significantly (p = 0.177) from the full-dose curve (AUC = 0.86). For all dose levels, the dark-field coefficient could distinguish between absent and at least mild emphysema with an AUC of 0.85. Conclusion Radiation dose reduction in dark-field imaging for emphysema assessment might be feasible, with median effective doses potentially as low as 11 µSv. Key points Question How does radiation dose reduction affect the diagnostic potential of dark-field chest radiographs? Findings For actual, regular-dose (36 µSv) dark-field radiographs, AUC was 0.86, and 0.84 for simulated low-dose images. Down to 7 µSv, the dark-field coefficient AUC was 0.85. Relevance statement Simulations suggest that the radiation dose in dark-field chest imaging could be lowered to 11 µSv, indicating the technique's potential for ultra-low-dose imaging, which could be especially beneficial for potential clinical screening applications in the future.

Subject terms

Humans; Radiation Dosage; Female; Pulmonary Emphysema; Male; Middle Aged; Aged; Radiography, Thoracic; Tomography, X-Ray Computed; ROC Curve

DOI: 10.1186/s41747-026-00796-x · PubMed: 42720851

Cite this article

Bast H, Schick RC, Koehler T, et al. Assessment of emphysema with simulated low-dose dark-field radiography. Eur Radiol Exp. 2026. doi:10.1186/s41747-026-00796-x

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Radiology & Imaging studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Research · Eur Radiol · Sep 9, 2026 · Radiology & Imaging, Digital Health & AI

Segmentation-based deep learning emphysema quantification using chest CT: improved accuracy and robustness vs LAA-950

Review · Eur Radiol Exp · Jan 5, 2026 · Radiology & Imaging, Cardiology

Ultra-high spatial resolution at photon-counting computed tomography: technical insights and sustainable applications in cardiothoracic imaging

Research · Eur Radiol Exp · Sep 8, 2026 · Pediatric · Radiology & Imaging, Pediatrics

Next-gen paediatric imaging: ultra-low dose chest photon-counting CT approaching chest radiograph doses

Research · Eur Radiol Exp · Sep 30, 2026 · Radiology & Imaging

Quantitative comparison of 68-keV monoenergetic, routine-dose, and low-dose 120-kVp CT for calcium-mimicking inserts in thoracic phantoms: effects of phantom size and reconstruction method

Systematic review · AJRCCM · Mar 24, 2025 · Pulmonology, Radiology & Imaging

Computed tomography densitometry is a validated biomarker for assessing emphysema in clinical trials