ResearchEuropean Radiology · Sep 9, 2026
Segmentation-based deep learning emphysema quantification using chest CT: improved accuracy and robustness vs LAA-950
Sotoudeh-Paima S, Ghojogh Nejad M, O'Sullivan-Murphy B, MacIntyre NR, Lynch DA, Samei E, et al
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Objectives
To develop a deep learning segmentation algorithm to enable accurate, reliable emphysema quantification while improving agreement with radiologist assessments and pulmonary function tests. Materials and methods
The model was developed using retrospective virtual and clinical datasets. Virtual data enabled pre-training using ground truth across controlled parameters, including scanners, doses, and reconstruction kernels, while clinical data enabled fine-tuning with expert-annotated emphysema masks. Segmentation accuracy was quantified using the Dice coefficient, and robustness was quantified using emphysema percentage consistency across imaging conditions. Model-based emphysema percentage was correlated with Fleischner visual scores (ordinal; 0-5) and pulmonary function tests (DLCO, FEV1pp, and FEV1/FVC) and compared to LAA-950. Statistical analysis included univariate/multivariate correlations. Quantitative assessment included Dice, bias, limits of agreement, and reproducibility coefficient. Results
Virtual data included 20 human models (mean age: 43 years ± 11 [SD], 10 men), and clinical data included multi-center cohorts of 101 patients (C1; 57 years ± 8, 54 men), 23 patients (C2; 57 years ± 7, 14 men), and 1159 patients (C3; 65 years ± 9, 586 men). The model outperformed LAA-950 in segmentation accuracy, achieving higher Dice scores across virtual (76.6% ± 8.8 vs 51.5% ± 23.5), C1 (48.4% ± 24.2 vs 22.5% ± 20.2), and C2 (64.8% ± 9.3 vs 32.7% ± 16.8) cohorts. Furthermore, analysis showed improved bias and limits of agreement (C1; 1.0% ± 4.3 vs 2.1% ± 15.1) and stronger correlations with visual scoring (C1; 0.77 vs 0.47) and pulmonary function tests (C3; DLCO multivariate R²: 0.31-0.32 vs 0.21-0.25). Conclusion
The proposed model provided a promising, clinically relevant alternative to LAA-950, improving accuracy and consistency in emphysema quantification and further aligning with radiologist assessments and lung function metrics. Key points
Question Can deep learning-based emphysema segmentation on CT improve the accuracy and robustness of emphysema quantification relative to the traditional LAA-950 biomarker? Findings The deep learning model outperformed LAA-950 in terms of accuracy and reproducibility and demonstrated stronger correlations with visual emphysema scores and pulmonary function tests. Clinical relevance The improved performance of the deep learning approach enables more reliable emphysema quantification across imaging conditions, with closer agreement to radiologist assessments and pulmonary function tests.
Topics
Humans; Deep Learning; Tomography, X-Ray Computed; Reproducibility of Results; Male; Female; Middle Aged; Retrospective Studies; Pulmonary Emphysema; Adult; Algorithms; Radiography, Thoracic
DOI: 10.1007/s00330-026-12800-4 · PubMed: 42717029
Spotted a mistake? Suggest a correction
More in Radiology & Imaging
ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging
Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment
ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging
Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
Classic signs in head and neck imaging-a quick guide for the radiology resident
ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging
Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease