ResearchResuscitation · Feb 25, 2026

Association between barriers of resuscitation and chest compression quality metrics during in-hospital cardiac arrest resuscitation attempts

Agervig F, Gedde AR, Østergård AV, Nettinger M, Müller SD, Nielsen RP, et al
Critical CareCardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Objective To investigate the association between barriers reported by cardiac arrest team members and chest compression quality during in-hospital cardiac arrest (IHCA) cardiopulmonary resuscitation (CPR) attempts. Methods This is a mixed-methods prospective cohort study. We sent post-event debriefing surveys to cardiac arrest team members following resuscitation attempts across four hospitals from 2017 to 2022. Likert-scale ratings and qualitative analysis of free-text comments were used to categorize events as having barriers present. We investigated the association between barriers and key chest compression quality metrics measured from defibrillators. The association was further examined for three predefined barrier categories: CPR quality, teamwork and communication. Results We included 313 IHCAs with complete defibrillator and survey data, of which 133 (42.5%) events had barriers reported. The odds ratio (OR) of having a CCF ≥80% was 0.55 (95% CI: 0.35-0.89) when barriers were reported. IHCAs with any reported barriers had an increase in the longest pause duration of 3.21 s (95% CI: -1.91 to 8.38) compared to IHCAs without reported barriers, while the OR for guideline-compliant compression rate was 1.02 (95% CI: 0.64-1.62). Communication barriers, but not teamwork and CPR quality barriers, were associated with lower odds of guideline-compliant chest compression rates (OR = 0.53; 95% CI: 0.29-0.95). Conclusion Barriers were frequently reported during IHCA and were associated with a significantly lower odds for a CCF ≥80% but not significantly associated with the longest pause duration and guideline-compliant chest compression rates. The category of communication barriers appeared to be the main driver of associations with chest compression quality metrics.

More on this topic

Cardiac arrest and resuscitation

Subject terms

Humans; Cardiopulmonary Resuscitation; Heart Arrest; Prospective Studies; Heart Massage; Female; Male; Defibrillators

DOI: 10.1016/j.resuscitation.2026.111030 · PubMed: 41759815

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Agervig F, Gedde AR, Østergård AV, et al. Association between barriers of resuscitation and chest compression quality metrics during in-hospital cardiac arrest resuscitation attempts. Resuscitation. 2026;221:111030. doi:10.1016/j.resuscitation.2026.111030

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Critical Care studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Meta-analysis n = 2,818 · Resuscitation · Oct 24, 2021 · Critical Care, Cardiology

Mechanical chest compressions were associated with higher rates of overall compression-induced injuries than manual compressions

Research · Resuscitation · Feb 16, 2026 · Pediatric · Critical Care, Pediatrics

The impact of tracheal intubation attempts on chest compression fraction during pediatric CPR: a report from the Videography in Pediatric Resuscitation (VIPER) collaborative

Secondary analysis of a trial n = 352 · J Am Heart Assoc · Jan 14, 2021 · Cardiology, Critical Care

Virtual reality training was associated with higher compliance with new cardiopulmonary resuscitation quality criteria

Research · Resuscitation · May 20, 2026 · Critical Care, Cardiology

Measuring transient return of spontaneous circulation and rearrest after in-hospital cardiac arrest: a prospective validation study

Research · Resuscitation · Jan 29, 2026 · Critical Care, Cardiology

Adherence to automated external defibrillator instructions during real-life in-hospital cardiac arrest: an analysis of device data