Visual abstractsVisuals
ResearchBJU International · Jul 7, 2026

Automated irrigation systems in mitigating laser-induced temperature during simulated ureteroscopy

Menzies-Wilson R, Williams J, Rhodes C, Glienke L, Roberts WW, Turney B
UrologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Objective To compare the temperature changes with laser activation when providing irrigation with a pressure bag vs a fluid management system (FMS). Materials and methods Benchtop experiments were performed with a LithoVue™ Elite (Boston Scientific Corp., Marlborough, MA, USA) flexible ureteroscope placed through an 11/13-F ureteric access sheath into a benchtop pelvicalyceal kidney model. Room temperature saline irrigation, via the scope, was provided either with a pressure bag or FMS. Both systems were pressurised to 200 mmHg and left for 10 min. After 10 min, a holmium:yttrium-aluminium-garnet laser was activated at 20, 40, or 60 W for 90 s. Flow rate, irrigation pressure, intrarenal pressure and calyceal temperature were recorded continuously. Experiments were repeated five times. Benchtop empirical temperature data were compared to mathematical model predictions. The mathematical model was then used to predict calyx temperature as a function of flow rate in in vivo conditions. Results Pressure-bag irrigation flow rate declined from ~38 to ~25 mL/min (36%) over 10 min, whereas the FMS maintained stable flow of ~45 mL/min. Intrarenal pressure remained ≤30 mmHg in all experiments. Consequently, the benchtop calyx mean (standard deviation) temperature rise with pressure bag vs FMS irrigation was: at 20 W 7.9 (1.0)°C vs 6.4 (0.6)°C (P = 0.02); at 40 W 12.8 (3.2)°C vs 10.3 (1.7)°C (P = 0.15); at 60 W 17 (3.4)°C vs 12.4 (1.2)°C (P = 0.02). Conclusion Irrigation flow rate is a key determinant of thermal risk during laser lithotripsy. An automated FMS can maintain consistent flow; mitigating temperature rise and thermal dose in a benchtop model.

Topics

Therapeutic Irrigation; Ureteroscopy; Lasers, Solid-State; Humans; Temperature; Ureteroscopes; Equipment Design

DOI: 10.1111/bju.70364 · PubMed: 42415229

Spotted a mistake? Suggest a correction

More in Urology

Meta-analysisVisual abstractEur Urol · Nov 17, 2026 · Urology

Epidemiology and Modifiable Risk Factors for Benign Prostatic Enlargement and Related Lower Urinary Tract Symptoms: A Systematic Review with Meta-analysis

Meta-analysisVisual abstractEur Urol · Nov 16, 2026 · Urology

Checkpoint inhibitor regimens benefit renal cell carcinoma patients with poor prognosis most

Which Patients with Advanced Clear Cell Renal Cell Carcinoma Benefit Most from First-line Checkpoint Inhibitor Combination Regimens: A Meta-analysis of Individual Patient Data and Aggregate Data from Randomised Trials

ReviewEur Urol · Nov 12, 2026 · Urology

Male factor infertility is influenced by genetics, environment, and lifestyle choices

Key Determinants and Clinical Impact of Male Factor Infertility: From Etiology to Treatment

ResearchEur Urol · Nov 12, 2026 · Urology

Nectin-4-targeted PET/CT compared to FDG PET/CT for urothelial carcinoma staging

Diagnostic Performance of Nectin-4-targeted [68Ga]Ga-DOTA-N188 PET/CT versus [18F]-FDG PET/CT for Staging of Locally Advanced and Metastatic Urothelial Carcinoma: A Prospective, Single-center, Phase 2 Feasibility Trial

ResearchPediatricEur Urol Oncol · Nov 7, 2026 · Urology

Robotic surgery worked as well as open surgery for Wilms tumor in selected cases

Exploring the Limits of Robotic Surgery for Wilms Tumor: A Descriptive Analysis