Automated software resulted in fewer errors and shorter scan times than manual cardiac MRI planning
Automated vs manual cardiac MRI planning: a single-center prospective evaluation of reliability and scan times
Key points
- Eighty-two patients were randomized to receive either manual cardiac magnetic resonance imaging planning or automated planning using prototype software.
- The automated group had a lower mean error rate of 0.45 compared to 1.13 in the manual group and a higher error-free rate of 70.5% versus 44.7%.
- Automated scans were shorter during free breathing at 30.3 minutes compared to 36.5 minutes for manual scans, though breath-hold durations were similar.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Glessgen C, Crowe LA, Wetzl J, et al. Automated vs manual cardiac MRI planning: a single-center prospective evaluation of reliability and scan times. Eur Radiol. 2025. doi:10.1007/s00330-025-11364-z