Randomized trialJAMA Network Open · Jan 2, 2025

Automatic Quality Control System and Adenoma Detection Rates During Routine Colonoscopy: A Randomized Clinical Trial

Liu J, Zhou R, Liu C, Liu H, Cui Z, Guo Z, et al
Gastroenterology & HepatologyOncologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Importance High-quality colonoscopy reduces the risks of colorectal cancer by increasing the adenoma detection rate. Routine use of an automatic quality control system (AQCS) to assist in colorectal adenoma detection should be considered. Objective To evaluate the effect of an AQCS on the adenoma detection rate among colonoscopists who were moderate- and low-level detectors during routine colonoscopy. Design, setting, and participants This multicenter, single-blind, randomized clinical trial was conducted at 6 centers in China from August 1, 2021, to September 30, 2022. Data were analyzed from March 1 to June 30, 2023. Individuals aged 18 to 80 years were enrolled. Exclusion criteria were a history of inflammatory bowel disease, advanced colorectal cancer, and polyposis syndromes; known colorectal polyps without complete removal previously; a history of colorectal surgery; known stenosis or obstruction with contraindication for biopsy or prior failed colonoscopy; pregnancy or lactation; and refusal to participate. Intention-to-treat and per-protocol analysis was used. Interventions Standard colonoscopy or AQCS-assisted colonoscopy. Main outcomes and measures Adenoma detection rate. Results A total of 1254 participants (mean [SD] age, 51.21 [12.10] years; 674 [53.7%] male) were randomized (627 standard colonoscopy, 627 AQCS-assisted colonoscopy). Intention-to-treat analysis showed a significantly higher adenoma detection rate in the AQCS-assisted group vs standard colonoscopy group (32.7% vs 22.6%; relative risk [RR], 1.60; 95% CI, 1.23-2.09; P < .001). The adenoma detection rates were significantly higher in the AQCS group when considering pathology (nonadvanced adenomas, 30.1% vs 21.2%; RR, 1.52; 95% CI, 1.16-1.99; P = .002), and morphology (flat or sessile, 29.3% vs 20.4%, RR, 1.52; 95% CI, 1.16-2.00; P = .003). Use of AQCS significantly increased the adenoma detection rate of both the lower-level detectors (30.0% vs 20.0%; RR, 1.71; 95% CI, 1.24-2.35; P = .001) and the medium-level detectors (38.1% vs 27.7%; RR, 1.61; 95% CI, 1.07-2.43; P = .02). Similar increases were found for adenoma detection rates in the academic and nonacademic centers (academic: 29.3% vs 20.8%; RR, 1.58; 95% CI, 1.10-2.29; P = .01; nonacademic: 36.1% vs 24.5%; RR, 1.74; 95% CI, 1.23-2.46; P = .002). The number of adenomas per colonoscopy was significantly higher in the AQCS-assisted group (0.86 vs 0.48; RR, 1.50; 95% CI, 1.17-1.91; P = .001). The mean withdrawal time without intervention was slightly increased with AQCS assistance (6.78 vs 6.46 minutes; RR, 1.38; 95% CI, 1.26-1.52; P < .001). No serious adverse events were reported. Conclusions and relevance In this randomized clinical trial, AQCS assistance during routine colonoscopy increased adenoma detection rates and several related polyp parameters compared with standard colonoscopy in the lower- and medium-level detectors in academic and nonacademic settings. Routine use of AQCS to assist in colorectal adenoma detection and quality improvement should be considered. Trial registration ClinicalTrials.gov Identifier: NCT04901130.

Topics

Humans; Colonoscopy; Female; Male; Middle Aged; Adenoma; Single-Blind Method; Adult; Colorectal Neoplasms; Quality Control; Aged; China

DOI: 10.1001/jamanetworkopen.2024.57241 · PubMed: 39883463 · Registered: NCT04901130

Cite this article

Liu J, Zhou R, Liu C, Liu H, Cui Z, Guo Z. Automatic Quality Control System and Adenoma Detection Rates During Routine Colonoscopy: A Randomized Clinical Trial. JAMA Netw Open. 2025. doi:10.1001/jamanetworkopen.2024.57241

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Randomized trial · Clin Gastroenterol Hepatol · Nov 2, 2023 · Gastroenterology & Hepatology

Effect of Real-Time Computer-Aided Polyp Detection System (ENDO-AID) on Adenoma Detection in Endoscopists-in-Training: A Randomized Trial

Randomized trial · Clin Gastroenterol Hepatol · Sep 14, 2021 · Gastroenterology & Hepatology, Digital Health & AI

Deep Learning Computer-aided Polyp Detection Reduces Adenoma Miss Rate: A United States Multi-center Randomized Tandem Colonoscopy Study (CADeT-CS Trial)

Randomized trial · Am J Gastroenterol · Apr 25, 2024 · Gastroenterology & Hepatology, Oncology

Improved Adenoma Detection Rate Using a Novel Colonoscopic Distal Attachment: A Multicenter Randomized Controlled Trial

Meta-analysis · Aliment Pharmacol Ther · Feb 18, 2022 · Gastroenterology & Hepatology, Oncology

Systematic review: non-endoscopic surveillance for colorectal neoplasia in individuals with Lynch syndrome

Randomized trial · Clin Gastroenterol Hepatol · Apr 8, 2021 · Gastroenterology & Hepatology, Oncology

Detection of Colorectal Neoplasms Using Linked Color Imaging: A Prospective, Randomized, Tandem Colonoscopy Trial