Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Jul 7, 2026

CE-MRA-FLOWnet: Fast and accurate generative artificial intelligence-based aortic hemodynamic mapping from contrast-enhanced magnetic resonance angiography

Dushfunian D, Berhane H, Johnson E, Dehadrai A, Markl M, Allen BD
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Four-dimensional (4D) flow magnetic resonance imaging (MRI) hemodynamic biomarkers (e.g., peak velocity and wall shear stress [WSS]) have shown promise for improved risk-stratification in patients with thoracic aortic disease (TAD). However, lengthy 4D flow scan times, complex data analysis and need for dedicated expertise limit clinical translation. In this study, we developed a fluid-physics informed deep generative adversarial neural network, CE-MRA-FLOWnet, to predict aortic hemodynamics directly from standard-of-care contrast-enhanced magnetic resonance angiography (CE-MRA) images. Methods We retrospectively identified 1392 patients (age: 52±12years, 1011 male, 954 with bicuspid aortic valve, BAV; 438 with tricuspid aortic valve, TAV) who underwent paired clinical 4D flow MRI and CE-MRA between 2011 and 2020 for suspected TAD. The CE-MRA-FLOWnet used CE-MRA data (1127 for network training, 265 for testing) to generate a prediction of aortic hemodynamics. 4D flow-measured aortic systolic three-dimensional (3D) blood flow velocity vector fields served as ground truth. Analysis included comparison of AI-derived and ground truth aortic systolic peak velocity (PV) and WSS, the relative area of the ascending aorta (AAo, %) exposed to elevated WSS, and aortic valve stenosis severity grading. The predictive value of CE-MRA-FLOWnet hemodynamics metrics was assessed in a subgroup of 133 BAV patients with known multi-year adverse outcomes. Results CE-MRA-FLOWnet training time was 8100 min; inference time per CE-MRA was 0.88±0.05 seconds. AI-derived PV showed strong regional agreement and low biases with ground truth 4D flow (0.00-0.04 m/s), and relative differences within 10.6%-12.7%. Aortic WSS also demonstrated minimal bias (-0.01-0.04 Pa) and close alignment of the area of elevated WSS between AI and 4D flow (19.6±15.1% vs. 19.3±16.2%, p=0.84). AS severity was accurately classified in 88% (233/265) of cases, with all grading errors limited to a one-grade difference (Kappa 0.84). Receiver operating characteristic (ROC) analysis showed that CE-MRA-FLOWnet derived hemodynamic metrics outperformed diameter alone for predicting adverse outcomes (PV area under the curve [AUC] = 0.73-0.76; WSS = 0.83-0.88; diameter = 0.52-0.62). Conclusion CE-MRA-FLOWnet accurately predicts aortic hemodynamics in TAD patients using standard-of-care CE-MRA images. Our results demonstrate potential for clinical integration by providing physicians with near real-time hemodynamic data from widely available clinical CE-MRA images.

DOI: 10.1016/j.jocmr.2026.102773 · PubMed: 42413872

Cite this article

Dushfunian D, Berhane H, Johnson E, Dehadrai A, Markl M, Allen BD. CE-MRA-FLOWnet: Fast and accurate generative artificial intelligence-based aortic hemodynamic mapping from contrast-enhanced magnetic resonance angiography. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102773

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Eur Radiol Exp · Nov 20, 2026 · Meta-analysis · Radiology & Imaging, Oncology

MRI radiomics of pancreatic tumours: a systematic review of methodological quality and imaging reproducibility

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity

EJNMMI Res · Nov 19, 2026 · Research · Radiology & Imaging

Small language model pipeline structures clinical information for dopamine transporter SPECT imaging reports

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity