Visual abstractsVisuals
ResearchEuropean Radiology · Jun 10, 2026

Comparative evaluation of generative AI models for chest radiograph report generation in the emergency department

Lim WH, Lee JY, Lee JH, Kim S, Kim H
Radiology & ImagingAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objectives To benchmark medical image-specific vision-language models (VLMs) against real-world radiologist-written reports, focusing on diagnostic quality, clinical acceptability, hallucinations, and language clarity. Materials and methods This retrospective study included adult patients who presented to the emergency department of a tertiary center between January 2022 and April 2025 and underwent same-day chest radiograph (CXR) and CT for febrile or respiratory symptoms. Reports from five VLMs (AIRead, Lingshu, MAIRA-2, MedGemma, and MedVersa) and radiologist-written reports were randomly presented and blindly evaluated by three thoracic radiologists using four criteria: RADPEER, clinical acceptability, hallucination, and language clarity. Comparative performance was assessed using generalized linear mixed models, with radiologist-written reports treated as the reference. Finding-level analyses were also performed with CT as a reference. Results A total of 478 patients (median age, 67 years [interquartile range, 50-78]; 282 males [59.0%]) were included. AIRead demonstrated the lowest RADPEER 3b rate (5.3% [76/1434] vs radiologists 13.9% [200/1434]; p Conclusion Medical VLMs for CXR report generation exhibited variable performance in report quality and diagnostic measures. Key points Question How do medical VLMs perform compared with radiologist-written reports regarding diagnostic quality, clinical acceptability, hallucinations, and language clarity for CXRs? Findings One non-open-source VLM achieved the lowest RADPEER 3b rate and highest acceptability with radiologist-level hallucinations, whereas other models showed inferior performance. Clinical relevance VLMs may support automated preliminary CXR reporting and serve as adjunct tools to enhance workflow efficiency and consistency. Although performance varied widely, carefully developed models approached radiologist-level quality, supporting continued refinement and targeted clinical integration.

Topics

Humans; Male; Radiography, Thoracic; Middle Aged; Retrospective Studies; Aged; Emergency Service, Hospital; Female; Generative Artificial Intelligence; Tomography, X-Ray Computed; Radiologists

DOI: 10.1007/s00330-026-12648-8 · PubMed: 42268300

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease