Visual abstractsVisuals
ResearchInsights into Imaging · Apr 22, 2026

Comparative evaluation of large language models for generating CAD-RADS 2.0-compliant diagnostic conclusions in cardiac CT reports

Lorusso G, Ruscino G, Spitaleri A, Morelli C, Greco S, Villanova I, et al
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Objectives Coronary computed tomography angiography (CCTA) has become a cornerstone in non-invasive CAD diagnosis and risk stratification. To standardize reporting and improve clinical decision-making, the CAD-RADS 2.0 system was introduced. This study evaluates the performance of four LLMs, GPT-4o, Gemini 2.0 Flash, DeepSeek V, and Copilot in generating CAD-RADS 2.0-compliant conclusions from standardized CCTA reports. Materials and methods A total of 196 anonymized CCTA reports were retrospectively analyzed. Each LLM was prompted to provide CAD-RADS 2.0 classifications and follow-up recommendations. Ground truth labels were assigned by a senior radiologist. Performance metrics (accuracy, precision, recall, F1-score), execution times, and agreement (Cohen's kappa) with expert interpretation were computed. Interobserver agreement between junior and senior radiologists was also assessed. Results LLMs demonstrated good-to-excellent agreement with expert classifications: DeepSeek V (κ = 0.771), Copilot (κ = 0.761), GPT-4o (κ = 0.759), and Gemini 2.0 Flash (κ = 0.634). DeepSeek V achieved the highest accuracy (91.83%). Intra-model consistency was perfect (κ = 1). However, LLMs failed to assign CAD-RADS modifiers. ChatGPT-4o provided the most accurate follow-up recommendations (71.94%). All LLMs outperformed radiologists in execution time (3-9 s vs. 15-20 s; p Conclusions Generic LLMs demonstrate promising performance in automating CAD-RADS 2.0 classification from CCTA reports. However, limitations in modifier assignment and recommendation accuracy highlight areas for refinement before clinical integration. Critical relevance statement This study explores the potential of large language models to facilitate standardized CAD-RADS 2.0 reporting from coronary CT angiography, highlighting a possible avenue to support workflow efficiency and clinical decision-making in non-invasive coronary artery disease evaluation. Key points LLMs demonstrated strong potential in automating CAD-RADS 2.0-compliant structured reporting for CCTA. LLMs could significantly enhance efficiency in radiological reporting. LLMs need further optimization before clinical integration.

DOI: 10.1186/s13244-026-02285-6 · PubMed: 42018072

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease