Risk-adapted screening detected advanced colorectal neoplasia at similar rates to colonoscopy and FIT
Comparison of Colonoscopy, Fecal Immunochemical Test, and Risk-Adapted Approach in a Colorectal Cancer Screening Trial (TARGET-C)
Clinical question: How do colonoscopy, fecal immunochemical test, and risk-adapted screening compare for colorectal cancer screening?
Why it matters: It was unclear how the screening yield and related cost of a risk-adapted approach compared with established strategies in population-based colorectal cancer screening.
- 19,373 participants were randomly assigned to one-time colonoscopy, annual fecal immunochemical test, or annual risk-adapted screening over three rounds.
- Detection rates for advanced neoplasia were 2.76% for colonoscopy, 2.17% for FIT, and 2.35% for risk-adapted screening, with no significant differences between groups.
- The cost to detect one advanced neoplasm was 6928 CNY for colonoscopy, 5821 CNY for FIT, and 6694 CNY for risk-adapted screening.