Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Oct 3, 2026

Comparison of Deep Learning-Based Free Breathing with Conventional Breath Holding CMR for Quantifying Degenerative Mitral Regurgitation

Chamay S, Horgan SJ, Animashaun IB, Jiang HY, Uretsky S
Radiology & ImagingAdult
Read the full paper free at the publisher ↗

Abstract

Background Cardiovascular magnetic resonance (CMR) imaging acquisition frequently relies on breath-holding, which poses challenges in patients with certain underlying comorbidities. A new technique consisting of deep learning-based accelerated 2D steady-state free precession (SSFP) cine imaging (Sonic DL Cine, GE HealthCare) allows for 1 heart beat free-breathing SSFP acquisition. This study aimed to demonstrate the accuracy of free-breathing acquisition SSFP using Sonic DL Cine and free-breathing phase contrast imaging versus standard breath holding for mitral regurgitation (MR) quantification in patients with degenerative MR. Methods Patients with degenerative MR were prospectively enrolled and underwent both breath-holding and free-breathing CMR. Short axis SSFP images and phase contrast images in the ascending aorta and proximal pulmonary artery were acquired using breath hold and free-breathing techniques to quantify ventricular volumes and blood flow in the ascending aorta and proximal pulmonary artery. MR volume and fraction were calculated for each patient using both techniques. Pearson's correlation and Bland-Altman plots were utilized to compare the two groups. Results A total of 27 patients (64 ± 9 years; 67% male) underwent 33 CMR studies. There was no statistically significant difference in left ventricular end-diastolic volume (LVEDV), LV stroke volume (SV), aortic phase contrast, pulmonary artery phase contrast, MR volume or MR fraction between breath-holding and free-breathing CMR. Pearson's correlation and Bland-Altman plots demonstrated excellent correlation and good agreement for LVEDV (r2 = 0.96; mean difference 0.7mL; p<0.001), LVESV (r2 = 0.93; mean difference 2mL; p<0.001), LVSV (r2 = 0.96; mean difference -1 mL; p<0.001), MR volume (r2 = 0.96; mean difference -1mL; p<0.001), and MR fraction (r2 = 0.93; mean difference -0.4mL; p<0.001). Conclusion Compared to conventional breath-holding, free-breathing CMR is feasible and comparable in the evaluation of ventricular parameters and MR quantification in patients with degenerative MR. This CMR technique would allow clinicians to accurately quantify MR in patients who are unable to perform conventional breath hold CMR.

DOI: 10.1016/j.jocmr.2026.102806 · PubMed: 42829055

Cite this article

Chamay S, Horgan SJ, Animashaun IB, Jiang HY, Uretsky S. Comparison of Deep Learning-Based Free Breathing with Conventional Breath Holding CMR for Quantifying Degenerative Mitral Regurgitation. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102806

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Eur Radiol Exp · Nov 20, 2026 · Meta-analysis · Radiology & Imaging, Oncology

MRI radiomics of pancreatic tumours: a systematic review of methodological quality and imaging reproducibility

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity

EJNMMI Res · Nov 19, 2026 · Research · Radiology & Imaging

Small language model pipeline structures clinical information for dopamine transporter SPECT imaging reports

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity