← Back to the study · · Download slide

Journal club handout · Crit Care Med · 2023-06-13

Comparison of Noninvasive Mechanical Ventilation With High-Flow Nasal Cannula, Face-Mask, and Helmet in Hypoxemic Respiratory Failure in Patients With COVID-19: A Randomized Controlled Trial

Key result: High-flow nasal cannula, helmet, and face-mask ventilation showed no difference in COVID-19 outcomes

Randomized control trialNo clear difference
Which noninvasive respiratory support is most effective for COVID-19 hypoxemic respiratory failure?
Who
151
Adult patients with COVID-19 and PaO2/FiO2 ratio less than 300 · Three tertiary centers in Oman
Compared
High-flow nasal cannula: 44% intubation rate
Face-mask continuous positive airway pressure: 45% intubation rate
Helmet continuous positive airway pressure: 46% intubation rate
Main outcome
Endotracheal intubation rate and mortality
Result: relative risk of intubation 0.97 (95% CI, 0.63-1.49) for HFNC
Bottom line: No difference in intubation rate or mortality was found among high-flow nasal cannula, face-mask, and helmet ventilation.
Limitation: The trial was stopped prematurely because of a decline in cases.
Crit Care Med · 2023-06-13 · Save PNG

Key points

Discussion prompts

  1. Would these patients look like yours? Who was left out?
  2. Is the main outcome one that matters to patients?
  3. Is the difference large enough to change what you do?

Cite: Al Hashim AH, Al Reesi A, Al Lawati NM, et al. Comparison of Noninvasive Mechanical Ventilation With High-Flow Nasal Cannula, Face-Mask, and Helmet in Hypoxemic Respiratory Failure in Patients With COVID-19: A Randomized Controlled Trial. Crit Care Med. 2023;51(11):1515-1526. doi:10.1097/CCM.0000000000005963

Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/comparison-of-noninvasive-mechanical-ventilation-with-high-flow-nasal-3kr0p0/ (AI-assisted from the abstract; check the paper before relying on it).