Objectives
To investigate the effect of CT slice thickness on radiomic features (RFs) in terms of reproducibility and discriminative power, and to assess whether a deep learning-based CT slice synthesis (DLS) algorithm can mitigate the adverse effects associated with thick-slice CT. Materials and methods
This retrospective multicenter study included 506 patients with lung nodules (245 benign, 261 malignant) from two independent cohorts, which were divided into a training set, internal validation set (IVS), and external validation set (EVS). Chest CT reconstructed at 1-mm and 5-mm slice thicknesses was analyzed. A DLS algorithm was applied to convert 5-mm CT into synthetic 1-mm CT. RFs were extracted from all CT types to construct radiomics models. Reproducibility was assessed using the concordance correlation coefficient (CCC) and compared with the Wilcoxon signed-rank test. Discriminative power was evaluated by the area under the receiver operating characteristic curve (AUC) and compared with DeLong's test. Results
The CCCs of DLS 1-mm CT were 0.48 ± 0.37 and 0.49 ± 0.37 in Cohort 1 and Cohort 2, respectively, significantly higher than real 5-mm CT (all p Conclusion
CT slice thickness substantially influences the reproducibility and discriminative power of RFs, whereas the DLS algorithm effectively mitigates the limitations associated with thick-slice CT. Critical relevance statement
Deep learning-based CT slice synthesis significantly reduces the slice thickness-related variability in radiomics feature reproducibility and discriminative power, providing a promising methodological approach to improve radiomics standardization and support its clinical translation. Key points
CT slice thickness variability substantially impairs radiomic feature reproducibility and discriminative performance, posing a major barrier to standardized radiomics analysis. Across two independent cohorts, deep learning-based slice synthesis mitigated the adverse effects of thick-slice CT on radiomic feature reproducibility and cross-thickness discriminative performance.
DOI: 10.1186/s13244-026-02338-w · PubMed: 42319610
Spotted a mistake? Suggest a correction
More in Radiology & Imaging
ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging
Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment
ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging
Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging
Classic signs in head and neck imaging-a quick guide for the radiology resident
ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging
Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease