Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Nov 28, 2025

Deep learning reconstruction for fast cardiovascular magnetic resonance imaging protocol: A comparative study with conventional cardiovascular magnetic resonance

Hua Y, Lu H, Wang S, Yue X, Du F, Zhang N, et al
Radiology & ImagingCardiologyDigital Health & AIAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Cardiovascular magnetic resonance (CMR) is a reference-standard modality for diagnosis of cardiac diseases, although its clinical application is restricted by prolonged acquisition times. Recently, artificial intelligence, particularly deep learning (DL), has exhibited the potential to accelerate the CMR acquisition through technological advances. Prospective validation of its diagnostic performance across multiple clinical sequences remains underexplored. This research aims to assess the functions of the compressed sensing artificial intelligence (CSAI) algorithm in accelerating CMR acquisition, enhancing image quality, and maintaining diagnostic accuracy versus conventional sensitivity encoding (SENSE) reconstruction. Methods A total of 105 participants scheduled for clinical CMR between February and August 2024 underwent both SENSE and CSAI-accelerated sequences containing Cine, T2 short TI inversion recovery (STIR), and late gadolinium enhancement (LGE) during a single session. The subjective image quality was assessed by a 5-point Likert scale. Quantitative image quality metrics were evaluated, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), edge sharpness, ventricular function, T2 signal intensity (SI) ratio, and LGE percentage. Results Using standard resolution, the acquisition time of CSAI-CMR was 57.4%(159.2/277.1) lower than that of SENSE CMR (159.2 ± 22.4 s vs 277.1 ± 30.4 s; P < 0.001). Higher subjective scores could be found in CSAI-Cine and CSAI-T2 STIR compared with SENSE CMR (P < 0.001). Quantitative analyses demonstrated superior SNR and CNR across CSAI sequences in comparison with SENSE CMR including Cine (SNR: 109.16 ± 20.36 vs 102.52 ± 21.93, CNR: 58.98 ± 24.43 vs 51.08 ± 23.37; both P < 0.001), T2 STIR (SNR: 98.17 ± 6.20 vs 81.77 ± 11.15; P < 0.001), and LGE (SNR: 38.02 ± 7.90 vs 32.54 ± 7.72, CNR: 22.24 ± 5.15 vs 19.09 ± 4.22; both P < 0.001). Edge sharpness was significantly improved by using CSAI-CMR (0.141 ± 0.06 pixel⁻¹ vs 0.105 ± 0.04 pixel⁻¹; P < 0.01). Functional parameters, both T2 SI ratio and LGE percentage, were comparable relatively (all P > 0.05). Conclusion DL reconstruction of CMR sequences reduced acquisition times by 57%(159.2/277.1) and enhanced image quality compared to conventional SENSE reconstruction, while maintaining consistent quantitative parameters and diagnostic accuracy across all sequences. These results advocate integrating DL-accelerated workflows into clinical practice.

Topics

Humans; Deep Learning; Predictive Value of Tests; Image Interpretation, Computer-Assisted; Magnetic Resonance Imaging, Cine; Reproducibility of Results; Female; Time Factors; Prospective Studies; Male; Middle Aged; Contrast Media

DOI: 10.1016/j.jocmr.2025.102017 · PubMed: 41318031

Cite this article

Hua Y, Lu H, Wang S, Yue X, Du F, Zhang N. Deep learning reconstruction for fast cardiovascular magnetic resonance imaging protocol: A comparative study with conventional cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2025. doi:10.1016/j.jocmr.2025.102017

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

J Cardiovasc Magn Reson · Mar 20, 2026 · Research · Radiology & Imaging, Cardiology

Interactive deep learning for myocardial scar segmentation using cardiovascular magnetic resonance

J Cardiovasc Magn Reson · Apr 16, 2026 · Research · Radiology & Imaging, Cardiology

Spatiotemporal deep learning for scar screening in cardiovascular magnetic resonance: Toward selective use of gadolinium

J Cardiovasc Magn Reson · Feb 17, 2026 · Research · Basic science · Radiology & Imaging, Digital Health & AI

Open-source pre-clinical image segmentation: mouse cardiac magnetic resonance imaging datasets with a deep learning segmentation framework

J Cardiovasc Magn Reson · Dec 24, 2025 · Research · Radiology & Imaging, Cardiology

Cardiac function assessment with deep-learning-based automatic segmentation of free-running four-dimensional whole-heart cardiovascular magnetic resonance

J Cardiovasc Magn Reson · Apr 15, 2026 · Research · Radiology & Imaging, Digital Health & AI

Customizing native T1 mapping: The effects of compressed sensing, deep learning-based denoising, and high-resolution on measurement of native myocardial T1