Injection volume and procedure timing influence vocal outcomes in patients with one paralyzed vocal fold
Determinants of clinical response to injection laryngoplasty in unilateral vocal fold paralysis: a systematic review and meta-analysis
Key points
- Researchers analyzed 82 studies involving patients undergoing their first injection laryngoplasty for unilateral vocal fold paralysis, which is when one vocal fold cannot move properly.
- Meta-regression showed that injection volume was a significant predictor of maximum phonation time, while the timing of the procedure was a significant predictor of the harmonics-to-noise ratio.
- The use of polydimethylsiloxane, a synthetic material, was associated with improved maximum phonation time, and autologous fat was associated with reduced roughness and dysphonia grades.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Safia A, Abd Elhadi U, Roch M, et al. Determinants of clinical response to injection laryngoplasty in unilateral vocal fold paralysis: a systematic review and meta-analysis. Int J Surg. 2024;110(11):7281-7310. doi:10.1097/JS9.0000000000001978