Visual abstractsVisuals
ResearchEJNMMI Research · Jul 7, 2026

Development and validation of a pulmonary embolism quantification method using single photon emission computed tomography ventilation and perfusion scintigraphy

Fernando H, Sibley-Allen C, Fowler C, Lefteris L
Radiology & ImagingPulmonologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Pulmonary embolism (PE) remains an important cause of cardiovascular death and morbidity worldwide. Conventionally, PE imaging is reported in a binary manner, with reports stating the presence or absence of a thrombus. No generally accepted graduated quantification systems are available to guide management or predict the development of acute or long-term complications. V/Q SPECT is a well-established method for diagnosing PE in acute and chronic settings. The use of volumetric perfusion and ventilation functional images could potentially calculate the volumetric PE burden. This project aimed to develop and optimise a volumetric V/Q SPECT PE quantification technique, utilising V/Q SPECT phantoms, 100 consecutive clinical V/Q SPECT studies, and advanced V/Q SPECT image analysis with semiautomated %PE quantification methods. Results Lung phantoms with PE defects of known volume demonstrated that the choice of acquisition, reconstruction parameters, and the volumetric cutoff threshold influences %PE results. The V/Q quotient image utilised a semiautomated technique with phantom-derived optimisation parameters, which was found to be the most accurate quantification method. Conclusion This study, combining phantom and clinical study analysis, developed a successful method for semiautomated V/Q SPECT %PE quantification, which has the potential utility of guiding patient management and outcome prediction.

DOI: 10.1186/s13550-026-01379-y · PubMed: 42412282

Cite this article

Fernando H, Sibley-Allen C, Fowler C, Lefteris L. Development and validation of a pulmonary embolism quantification method using single photon emission computed tomography ventilation and perfusion scintigraphy. EJNMMI Res. 2026. doi:10.1186/s13550-026-01379-y

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

Insights Imaging · Nov 20, 2026 · Research · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Eur Radiol Exp · Nov 20, 2026 · Meta-analysis · Radiology & Imaging, Oncology

MRI radiomics of pancreatic tumours: a systematic review of methodological quality and imaging reproducibility

Insights Imaging · Nov 19, 2026 · Research · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity

EJNMMI Res · Nov 19, 2026 · Research · Radiology & Imaging

Small language model pipeline structures clinical information for dopamine transporter SPECT imaging reports

Insights Imaging · Nov 18, 2026 · Research · Radiology & Imaging

MRI detected placenta accreta spectrum with 100 percent sensitivity