Visual abstractsVisuals
ResearchInsights into Imaging · Apr 18, 2026

Development and validation of fat-corrected virtual MR elastography to assess fibrosis stage in metabolic dysfunction-associated steatotic liver disease

Yuan J, Xu X, Yan F, Qin Z, Yan H, Yang W, et al
Radiology & ImagingAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objectives This study aimed to develop and validate a fat-corrected virtual magnetic resonance elastography (FC-vMRE) framework based on diffusion-weighted imaging (DWI) to assess liver fibrosis in patients with metabolic dysfunction-associated steatotic liver disease (MASLD). Materials and methods A total of 463 MASLD patients underwent multi-b-values (0-1500 s/mm²) DWI acquisition, proton density fat fraction (PDFF), and conventional magnetic resonance elastography (MRE). Apparent diffusion coefficient (ADC) parameters were calculated with or without fat correction (based on PDFF). Using the training cohort (n = 361), ADC-to-MRE formulas were derived to compute virtual MRE (vMRE) and FC-vMRE. In the validation cohort (n = 102, with biopsy), the diagnostic performance of vMRE, FC-vMRE, and MRE for fibrosis staging was compared. Results ADC200-1200 demonstrated the strongest correlation with MRE values (R = -0.706, p Conclusion FC-vMRE provides a clinically promising alternative requiring only standard MRI equipment, effectively correcting for fat-related confounding in MASLD, and demonstrating encouraging diagnostic concordance with MRE and histology. This approach shows potential for broader clinical implementation. Critical relevance statement Fat-corrected virtual MRE using diffusion-weighted imaging provides promising fibrosis staging accuracy to conventional magnetic resonance elastography in metabolic dysfunction-associated steatotic liver disease patients without requiring specialized hardware. Key points Fat infiltration confounds diffusion measurements in metabolic steatotic liver disease. Fat-corrected virtual MRE showed superior agreement with standard MRE. Hardware-free fibrosis assessment enables accessible liver stiffness measurement.

DOI: 10.1186/s13244-026-02287-4 · PubMed: 42000984

Spotted a mistake? Suggest a correction

More in Radiology & Imaging

ResearchInsights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated prognostic system predicts disease-free survival in pancreatic cancer patients

Enhanced prognosis stratification following surgery for pancreatic ductal adenocarcinoma to optimize clinical decisions by reflecting tumor heterogeneity and microenvironment

ResearchInsights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting CT localized parathyroid adenomas with 67.3% to 83.7% sensitivity

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Advancing placenta accreta spectrum diagnosis: is 3-T MRI or combined MRI with ultrasound the answer?

ResearchInsights Imaging · Nov 18, 2026 · Radiology & Imaging

Classic imaging signs aid diagnosis in head and neck radiology

Classic signs in head and neck imaging-a quick guide for the radiology resident

ResearchInsights Imaging · Nov 15, 2026 · Radiology & Imaging

Automated carotid plaque quantification helps identify obstructive coronary artery disease

Carotid CTA with automated plaque quantification for risk stratification of coexisting obstructive coronary artery disease