ResearchThe BMJ · Sep 14, 2022

Diagnostic accuracy of covid-19 rapid antigen tests with unsupervised self-sampling in people with symptoms in the omicron period: cross sectional study

Schuit E, Venekamp RP, Hooft L, Veldhuijzen IK, van den Bijllaardt W, Pas SD, et al
Infectious DiseaseAdult
Read the full paper free at PubMed Central ↗

Abstract

Objective To assess the performance of rapid antigen tests with unsupervised nasal and combined oropharyngeal and nasal self-sampling during the omicron period. Design Prospective cross sectional diagnostic test accuracy study. Setting Three public health service covid-19 test sites in the Netherlands, 21 December 2021 to 10 February 2022. Participants 6497 people with covid-19 symptoms aged ≥16 years presenting for testing. Interventions Participants had a swab sample taken for reverse transcription polymerase chain reaction (RT-PCR, reference test) and received one rapid antigen test to perform unsupervised using either nasal self-sampling (during the emergence of omicron, and when omicron accounted for >90% of infections, phase 1) or with combined oropharyngeal and nasal self-sampling in a subsequent (phase 2; when omicron accounted for >99% of infections). The evaluated tests were Flowflex (Acon Laboratories; phase 1 only), MPBio (MP Biomedicals), and Clinitest (Siemens-Healthineers). Main outcome measures The main outcomes were sensitivity, specificity, and positive and negative predictive values of each self-test, with RT-PCR testing as the reference standard. Results During phase 1, 45.0% (n=279) of participants in the Flowflex group, 29.1% (n=239) in the MPBio group, and 35.4% ((n=257) in the Clinitest group were confirmatory testers (previously tested positive by a self-test at own initiative). Overall sensitivities with nasal self-sampling were 79.0% (95% confidence interval 74.7% to 82.8%) for Flowflex, 69.9% (65.1% to 74.4%) for MPBio, and 70.2% (65.6% to 74.5%) for Clinitest. Sensitivities were substantially higher in confirmatory testers (93.6%, 83.6%, and 85.7%, respectively) than in those who tested for other reasons (52.4%, 51.5%, and 49.5%, respectively). Sensitivities decreased from 87.0% to 80.9% (P=0.16 by χ2 test), 80.0% to 73.0% (P=0.60), and 83.1% to 70.3% (P=0.03), respectively, when transitioning from omicron accounting for 29% of infections to >95% of infections. During phase 2, 53.0% (n=288) of participants in the MPBio group and 44.4% (n=290) in the Clinitest group were confirmatory testers. Overall sensitivities with combined oropharyngeal and nasal self-sampling were 83.0% (78.8% to 86.7%) for MPBio and 77.3% (72.9% to 81.2%) for Clinitest. When combined oropharyngeal and nasal self-sampling was compared with nasal self-sampling, sensitivities were found to be slightly higher in confirmatory testers (87.4% and 86.1%, respectively) and substantially higher in those testing for other reasons (69.3% and 59.9%, respectively). Conclusions Sensitivities of three rapid antigen tests with nasal self-sampling decreased during the emergence of omicron but was only statistically significant for Clinitest. Sensitivities appeared to be substantially influenced by the proportion of confirmatory testers. Sensitivities of MPBio and Clinitest improved after the addition of oropharyngeal to nasal self-sampling. A positive self-test result justifies prompt self-isolation without the need for confirmatory testing. Individuals with a negative self-test result should adhere to general preventive measures because a false negative result cannot be ruled out. Manufacturers of MPBio and Clinitest may consider extending their instructions for use to include combined oropharyngeal and nasal self-sampling, and other manufacturers of rapid antigen tests should consider evaluating this as well.

Abstract reproduced under the article’s CC BY NC licence.

More on this topic

COVID-19

Subject terms

Humans; Citric Acid; Copper Sulfate; COVID-19; COVID-19 Testing; Cross-Sectional Studies; Prospective Studies; Sodium Bicarbonate; Specimen Handling; Netherlands

DOI: 10.1136/bmj-2022-071215 · PubMed: 36104069

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Schuit E, Venekamp RP, Hooft L, et al. Diagnostic accuracy of covid-19 rapid antigen tests with unsupervised self-sampling in people with symptoms in the omicron period: cross sectional study. BMJ. 2022;378:e071215. doi:10.1136/bmj-2022-071215

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Infectious Disease studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Randomized trial n = 23,102 · Thorax · May 19, 2023 · Pulmonology, Infectious Disease

Oropharyngeal swabs had higher detection rates than nasopharyngeal swabs or saliva for COVID-19 testing

Meta-analysis n = 7,332 · Ann Intern Med · Jan 12, 2021 · Infectious Disease

Saliva sampling was nearly as sensitive as nasopharyngeal swabs for SARS-CoV-2 detection

Research · JAMA · Aug 27, 2022 · Pediatric · Pediatrics, Infectious Disease

Concordance of SARS-CoV-2 Results in Self-collected Nasal Swabs vs Swabs Collected by Health Care Workers in Children and Adolescents

Research · Lancet · Aug 8, 2022 · Infectious Disease

Persistence of somatic symptoms after COVID-19 in the Netherlands: an observational cohort study

Systematic review · Emerg Infect Dis · Feb 24, 2021 · Infectious Disease

Pooling sputum samples for tuberculosis testing may maintain high accuracy while saving cartridges