New commercial blood tests for tuberculosis infection show varying accuracy compared to current standards
Diagnostic Performance of New Commercial Interferon-Gamma Release Assays for Mycobacterium tuberculosis Infection: An Updated Systematic Review and Meta-analysis
Clinical question: How do new commercial interferon-gamma release assays compare to WHO-endorsed assays?
Why it matters: Policy updates are needed for tuberculosis testing because new commercial blood tests have been developed since the World Health Organization last endorsed specific assays.
- Researchers reviewed 39 reports describing 8 new interferon-gamma release assays, which are blood tests used to detect tuberculosis infection.
- The STANDARD E TB-Feron test had a non-significant sensitivity difference of -2.8% and a specificity difference of -3.6% compared to the QFT-Plus test.
- The LIAISON XL Analyzer showed a specificity that was 0.1% higher than the QFT-Plus/QFT-GIT tests with a pooled kappa agreement of 0.846.
Limitation the authors note: The overall certainty of evidence remains low due to risk of bias and imprecision.