Randomized trialAmerican Journal of Emergency Medicine · Sep 17, 2024

Drones reduce the time to defibrillation in a highly visited non-urban area: A randomized simulation-based trial

van Veelen MJ, Vinetti G, Dal Cappello T, Eisendle F, Mejia-Aguilar A, Parin R, et al
Emergency MedicineAdult
Read the full paper free at the publisher ↗

Abstract

Introduction Out-of-hospital cardiac arrest (OHCA) has a high global incidence and mortality rate, with early defibrillation significantly improving survival. Our aim was to assess the feasibility of autonomous drone delivery of automated external defibrillators (AED) in a non-urban area with physical barriers and compare the time to defibrillate (TTD) with bystander retrieval from a public access defibrillator (PAD) point and helicopter emergency medical services (HEMS) physician performed defibrillation. Methods This randomized simulation-based trial with a cross-over design included bystanders performing AED retrievals either delivered by automated drone flight or on foot from a PAD point, and simulated HEMS interventions. The primary outcome was the time to defibrillation, with secondary outcomes comparing workload, perceived physical effort, and ease of use. Results Thirty-six simulations were performed. Drone-delivered AED intervention had a significantly shorter TTD [2.2 (95 % CI 2.0-2.3) min] compared to PAD retrieval [12.4 (95 % CI 10.4-14.4) min] and HEMS [18.2 (95 % CI 17.1-19.2) min]. The self-reported physical effort on a visual analogue scale for drone-delivered AED was significantly lower versus PAD [2.5 (1 - 22) mm vs. 81 (65-99) mm, p = 0.02]. The overall mean workload measured by NASA-TLX was also significantly lower for drone delivery compared to PAD [4.3 (1.2-11.7) vs. 11.9 (5.5-14.5), p = 0.018]. Conclusion The use of drones for automated AED delivery in a non-urban area with physical barriers is feasible and leads to a shorter time to defibrillation. Drone-delivered AEDs also involve a lower workload and perceived physical effort than AED retrieval on foot.

Topics

Humans; Out-of-Hospital Cardiac Arrest; Defibrillators; Cross-Over Studies; Male; Female; Electric Countershock; Adult; Time-to-Treatment; Emergency Medical Services; Manikins; Air Ambulances

DOI: 10.1016/j.ajem.2024.09.036 · PubMed: 39305698

Cite this article

van Veelen MJ, Vinetti G, Dal Cappello T, Eisendle F, Mejia-Aguilar A, Parin R. Drones reduce the time to defibrillation in a highly visited non-urban area: A randomized simulation-based trial. Am J Emerg Med. 2024. doi:10.1016/j.ajem.2024.09.036

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Research · Ann Emerg Med · Jun 11, 2026 · Emergency Medicine, Cardiology

Emergency Medical Services Equipment Use in the Emergency Department and Time to Care for Those With Out-of-Hospital Cardiac Arrest

Research · J Am Heart Assoc · Apr 22, 2026 · Cardiology, Critical Care

Functional Access to Public Defibrillators and Out-of-Hospital Cardiac Arrest Outcomes: A Population-Based Geospatial Analysis in Korea

Research · Scand J Trauma Resusc Emerg Med · Mar 13, 2026 · Emergency Medicine, Cardiology

Barriers and enablers to public access defibrillation - an international RAND-UCLA consensus study

Research · J Am Heart Assoc · Jul 31, 2026 · Cardiology, Critical Care

Timing of Public-Access Defibrillation for Patients With Out-of-Hospital Cardiac Arrest: A Nationwide Cohort Study Using Time-Dependent Propensity Score Sequential Matching Approach

Randomized trial · Resuscitation · May 4, 2026 · Critical Care, Cardiology

Manual pressure augmentation during defibrillation did not improve survival after out-of-hospital cardiac arrest