Dual-hormone artificial pancreas for glucose control in type 1 diabetes: A meta-analysis
Key result: Dual-hormone artificial pancreas matched single-hormone systems for time in target range
Meta-analysis of 17 randomized crossover trialsMixed results
Is dual-hormone artificial pancreas effective and safe for type 1 diabetes?
Who
438
People with type 1 diabetes
Compared
Dual-hormone artificial pancreas
Single-hormone, SAP/CSII, or PLGS
Main outcome
Percent time in target range (3.9-10 mmol/L)
Result: MD 2.69% (95% CI -0.38 to 5.76) vs SAP/CSII MD 16.05% (95% CI 12.06 to 20.05)
Bottom line: Dual-hormone systems increase time in target range compared to single-hormone systems but may increase gastrointestinal symptom risk.
Diabetes Obes Metab · 2022-06-21 · Save PNG
Key points
- 17 randomized crossover trials with 438 participants compared dual-hormone artificial pancreas with single-hormone, pump, or low glucose suspend systems.
- Dual-hormone systems showed no significant difference in time in target versus single-hormone (MD 2.69%, 95% CI -0.38 to 5.76).
- Dual-hormone systems increased time in target versus pump systems (16.05%) and low glucose suspend systems (6.89%).
Why it matters: Applies to people with type 1 diabetes; dual-hormone systems offer similar glucose control to single-hormone systems but better control than pumps.
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: Zeng B, Jia H, Gao L, Yang Q, Yu K, Sun F. Dual-hormone artificial pancreas for glucose control in type 1 diabetes: A meta-analysis. Diabetes Obes Metab. 2022;24(10):1967-1975. doi:10.1111/dom.14781
Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/dual-hormone-artificial-pancreas-for-glucose-control-in-type-1-192guu6/ (AI-assisted from the abstract; check the paper before relying on it).