Dual-hormone artificial pancreas systems increased time in target range compared to single-hormone or sensor-augmented pumps
Dual-hormone artificial pancreas for glucose control in type 1 diabetes: A meta-analysis
Clinical question: Is dual-hormone artificial pancreas effective and safe for type 1 diabetes?
Why it matters: It was unknown how dual-hormone artificial pancreas systems compare to single-hormone systems, sensor-augmented pumps, or predictive low glucose suspend systems regarding glucose control and safety.
- Researchers analyzed 17 randomized crossover trials involving 438 participants with type 1 diabetes to compare dual-hormone artificial pancreas systems against other technologies.
- Dual-hormone systems resulted in 16.05% more time in target range compared to sensor-augmented pumps or continuous subcutaneous insulin infusion and 6.89% more compared to predictive low glucose suspend systems.
- Compared to single-hormone systems, dual-hormone systems showed no significant difference in time in target range and were associated with an increased risk of gastrointestinal symptoms.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Zeng B, Jia H, Gao L, Yang Q, Yu K, Sun F. Dual-hormone artificial pancreas for glucose control in type 1 diabetes: A meta-analysis. Diabetes Obes Metab. 2022. doi:10.1111/dom.14781
Spotted a mistake? Suggest a correction
The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.