Meta-analysisEuropean Journal of Cardio-Thoracic Surgery · Feb 9, 2024

Early and mid-term outcomes after aortic valve replacement using a novel tissue bioprosthesis: a systematic review

Sef D, Thet MS, Klokocovnik T, Luthra S
Cardiothoracic & Vascular SurgeryCardiologyPhysical Medicine & RehabilitationAdult
Read the full paper free at the publisher ↗

Abstract

Objectives While current data show a clear trend towards the use of bioprosthetic valves during aortic valve replacement (AVR), durability of bioprosthetic valves remains the most important concern. We conducted a 1st systematic review of all available evidence that analysed early and mid-term outcomes after AVR using the Inspiris RESILIA™ bioprosthesis. Methods A systematic literature search was performed to identify all relevant studies evaluating early and mid-term outcomes after AVR using the Inspiris RESILIA bioprosthesis and including at least 20 patients with no restriction on the publication date. Subgroup meta-analysis was performed to compare Inspiris RESILIA and PERIMOUNT Magna Ease bioprosthesis and to pool the early postoperative mortality and stroke rates. Results A total of 416 studies were identified, of which 15 studies met the eligibility criteria. The studies included a total of 3202 patients with an average follow-up of up to 5.3 years. The average age of patients across the studies was 52.2-75.1 years. Isolated AVR was performed in 39.0-86.4% of patients. In-hospital or 30-day postoperative mortality was 0-2.8%. At the mid-term follow-up, freedom from all-cause mortality was up to 85.4%. Among studies with mid-term follow-up, trace/mild paravalvular leak was detected in 0-3.0%, while major paravalvular leak was found only in up to 2.0% of patients. No statistically significant differences in terms of mortality (P = 0.98, odds ratio 1.02, 95% confidence interval 0.36-2.83) and stroke (P = 0.98, odds ratio 1.01, 95% confidence interval 0.38-2.73) between the Inspiris RESILIA bioprosthesis and PERIMOUNT Magna Ease bioprosthesis were observed in the subgroup meta-analysis. Conclusions Mid-term data on the safety and haemodynamic performance of the novel aortic bioprosthesis are encouraging. Further comparative studies with other bioprostheses and longer follow-up are still required to endorse durability and safety of the novel bioprosthesis.

Topics

Humans; Bioprosthesis; Heart Valve Prosthesis; Aortic Valve; Heart Valve Prosthesis Implantation; Treatment Outcome; Prosthesis Design; Postoperative Complications; Aged

DOI: 10.1093/ejcts/ezae045 · PubMed: 38331412

Cite this article

Sef D, Thet MS, Klokocovnik T, Luthra S. Early and mid-term outcomes after aortic valve replacement using a novel tissue bioprosthesis: a systematic review. Eur J Cardiothorac Surg. 2024. doi:10.1093/ejcts/ezae045

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Randomized trial · J Am Heart Assoc · May 15, 2025 · Cardiology, Surgery

Trial design compares redo heart surgery to valve-in-valve transcatheter replacement in low-risk patients

Randomized trial · Eur J Cardiothorac Surg · Jun 13, 2021 · Cardiothoracic & Vascular Surgery, Cardiology

Perioperative platelet reduction after sutureless or stented valve implantation: results from the PERSIST-AVR controlled randomized trial

Randomized trial · Eur J Cardiothorac Surg · Mar 16, 2022 · Cardiothoracic & Vascular Surgery, Cardiology

Pacemaker implantation after sutureless or stented valve: results from a controlled randomized trial

Meta-analysis · Eur J Cardiothorac Surg · Feb 1, 2021 · Cardiothoracic & Vascular Surgery, Cardiology

Aortic valve neocuspidization with autologous pericardium in adult patients: UK experience and meta-analytic comparison with other aortic valve substitutes

Meta-analysis · J Thorac Cardiovasc Surg · Jan 14, 2022 · Cardiothoracic & Vascular Surgery, Cardiology

Structural valve degeneration of bioprosthetic aortic valves: A network meta-analysis