Abstract

Objectives Sutureless aortic valves demonstrated non-inferiority to standard stented valves for major cardiovascular and cerebral events at 1 year after aortic valve replacement. We aim to assess the factors correlating with permanent pacemaker implantation (PPI) in both cohorts. Methods PERSIST-AVR is a prospective, randomized, open-label trial. Patients undergoing aortic valve replacement were randomized to receive a sutureless aortic valve replacement (Su-AVR) or stented sutured bioprosthesis (SAVR). Multivariable analysis was performed to identify possible independent risk factors associated with PPI. A logistic regression analysis was performed to estimate the risk of PPI associated to different valve size. Results The 2 groups (Su-AVR; n = 450, SAVR n = 446) were well balanced in terms of preoperative risk factors. Early PPI rates were 10.4% in the Su-AVR group and 3.1% in the SAVR. PPI prevalence correlated with valve size XL (P = 0.0119) and preoperative conduction disturbances (P = 0.0079) in the Su-AVR group. No predictors were found in the SAVR cohort. Logistic regression analysis showed a significantly higher risk for PPI with size XL compared to each individual sutureless valve sizes [odds ratio (OR) 0.272 vs size S (95%confidence interval 0.07-0.95), 0.334 vs size M (95% CI 0,16-0; 68), 0.408 vs size L (95% CI 0,21-0.81)] but equivalent risk of PPI rates for all other combination of valve sizes. Conclusions Su-AVR is associated with higher PPI rate as compared to SAVR. However, the increased PPI rate appears to be size-dependent with significant higher rate only for size XL. The combination of preoperative conduction disorder and a size XL can lead to a higher probability of early PPI in Su-AVR. Clinical trial registration number NCT02673697.

Topics

Aortic Valve; Aortic Valve Stenosis; Bioprosthesis; Heart Valve Prosthesis; Heart Valve Prosthesis Implantation; Humans; Pacemaker, Artificial; Prospective Studies; Prosthesis Design; Risk Factors; Treatment Outcome

DOI: 10.1093/ejcts/ezac164 · PubMed: 35290444 · Registered: NCT02673697

Cite this article

Lorusso R, Ravaux JM, Pollari F, Folliguet TA, Kappert U, Meuris B. Pacemaker implantation after sutureless or stented valve: results from a controlled randomized trial. Eur J Cardiothorac Surg. 2022. doi:10.1093/ejcts/ezac164

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, by email. Free.

Get the weekly digest

Similar articles

Randomized trial · Eur J Cardiothorac Surg · Jun 13, 2021 · Cardiothoracic & Vascular Surgery, Cardiology

Perioperative platelet reduction after sutureless or stented valve implantation: results from the PERSIST-AVR controlled randomized trial

Meta-analysis · Eur J Cardiothorac Surg · Feb 1, 2021 · Cardiothoracic & Vascular Surgery, Cardiology

Aortic valve neocuspidization with autologous pericardium in adult patients: UK experience and meta-analytic comparison with other aortic valve substitutes

Randomized trial · Eur J Cardiothorac Surg · Jul 20, 2023 · Cardiothoracic & Vascular Surgery, Cardiology

5-Year haemodynamic performance of three aortic bioprostheses. A randomized clinical trial

Randomized trial · J Am Heart Assoc · May 15, 2025 · Cardiology, Surgery

Trial design compares redo heart surgery to valve-in-valve transcatheter replacement in low-risk patients

Meta-analysis · Eur J Cardiothorac Surg · Oct 19, 2021 · Cardiothoracic & Vascular Surgery, Cardiology

Transcatheter aortic valve replacement for structural degeneration of previously implanted transcatheter valves (TAVR-in-TAVR): a systematic review