Carpentier Perimount Magna Ease showed better blood flow performance than two other aortic valves
5-Year haemodynamic performance of three aortic bioprostheses. A randomized clinical trial
Single-centre randomized clinical trialMixed results
How do three aortic bioprostheses compare in haemodynamic performance at 5 years?
Who
154
Patients receiving aortic bioprostheses · Single-centre
Compared
Carpentier Perimount Magna Ease: mean aortic gradient 12.3 mmHg (interquartile range 7.8-17.5)
Crown Phospholipid Reduction Treatment: mean aortic gradient 15 mmHg (IQR 10.8-31.9)
Trifecta: mean aortic gradient 14.7 mmHg (IQR 8.2-55)
Main outcome
Haemodynamic performance quantified by in vivo echocardiograms
Bottom line: The Carpentier Perimount Magna Ease had the best haemodynamic performance at the 5-year follow-up compared to other valves.
Eur J Cardiothorac Surg · 2023-07-20 · Save PNG
Clinical question: How do three aortic bioprostheses compare in haemodynamic performance at 5 years?
Key points
- Researchers compared 154 patients receiving either the Carpentier Perimount Magna Ease, Crown PRT, or Trifecta bovine pericardial valves over 5 years.
- The Carpentier Perimount Magna Ease had a mean aortic gradient of 12.3 mmHg compared to 15 mmHg for Crown PRT and 14.7 mmHg for Trifecta.
- Survival from all-cause mortality at 5 years was 74.8% and the cumulative incidence of severe structural valve degeneration was 9.5% in the Trifecta group.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Montero Cruces L, Carnero Alcázar M, Pérez Camargo D, et al. 5-Year haemodynamic performance of three aortic bioprostheses. A randomized clinical trial. Eur J Cardiothorac Surg. 2023;64(2). doi:10.1093/ejcts/ezad261
Spotted a mistake? Suggest a correction