ResearchThe BMJ · Sep 30, 2026

Robotic hip replacements linked to fewer malposition revisions than conventional surgery

Early national comparison of robotic versus conventional hip replacements for arthritis using National Joint Registry data: target trial emulation study

Mohammad HR, Judge A, Griffin XL, Murray DW
Orthopedics & Sports MedicineAdult
Key points

Limitation the authors note: The observational design means unmeasured and residual confounding cannot be ruled out.

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.

Was this summary helpful?

Read the full paper free at the publisher ↗⬇ Slide🖨 Handout

Abstract

Objectives To evaluate the early comparative effectiveness of robotic versus conventional total hip replacement (THR) in the UK. Design Target trial emulation study. Setting Public and private hospitals using data from the National Joint Registry of England, Wales, Northern Ireland, the Isle of Man, Guernsey, and Jersey. Participants 666 283 THRs performed between 2018 and 2024; 656 080 were conventional THRs and 10 203 were robotic THRs. Main outcome measures Five year THR implant survival (mean 2.5 year follow-up), all cause revision risk, cause specific revision risk, malpositioning revision risk, intraoperative complications, and patient survival up to five years. Kaplan-Meier survival analysis, Cox proportional hazards regression, and Fine and Gray models were used. Propensity score matching created comparable treatment groups to estimate the average treatment effect in the treated population. Results The five year implant survival of the matched conventional and robotic THR groups was 98.8% (95% confidence interval (CI) 98.6% to 99.0%) and 98.8% (CI 98.3% to 99.1%), respectively, with no difference in revision risk between groups (hazard ratio 0.96, 95% CI 0.75 to 1.22; P=0.73). Cause specific revision risk and intraoperative complication risks did not differ between groups. However, a significantly lower risk of revisions related to implant malposition (dislocation, leg length discrepancy, and malalignment) was observed in the robotic group (hazard ratio 0.53, 95% CI 0.30 to 0.93; P=0.03). The five year patient survival of the matched conventional and robotic THR groups was 96.3% (95% CI 95.8% to 96.8%) and 96.2% (95.2% to 97.0%), respectively, with no difference in all cause mortality risk (hazard ratio 1.12, 95% CI 0.95 to 1.34; P=0.17). Conclusions No significant differences were found in overall THR or patient survival, cause specific revision, or intraoperative complication risks between robotic and conventional groups. Robotic THR was associated with a lower revision risk from causes related to implant malpositioning. However, the possibility of unmeasured and residual confounding cannot be ruled out owing to the observational design. These results highlight the importance of careful evaluation of robotic technology in publicly funded healthcare systems because of the substantially higher capital and procedural costs.

Abstract reproduced under the article’s CC BY NC licence.

More on this topic

Osteoarthritis

Subject terms

Humans; Arthroplasty, Replacement, Hip; Registries; Reoperation; Robotic Surgical Procedures; Aged; United Kingdom; Female; Male; Prosthesis Failure; Osteoarthritis, Hip; Middle Aged

DOI: 10.1136/bmj-2026-100709 · PubMed: 42815970

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Mohammad HR, Judge A, Griffin XL, Murray DW. Early national comparison of robotic versus conventional hip replacements for arthritis using National Joint Registry data: target trial emulation study. BMJ. 2026;394:e100709. doi:10.1136/bmj-2026-100709

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Orthopedics & Sports Medicine studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Research · BMJ · Sep 30, 2026 · Orthopedics & Sports Medicine

Robotic and conventional knee replacements showed similar early survival rates in UK registry data

Meta-analysis n = 13,864 · Int J Surg · Mar 11, 2022 · Surgery, Orthopedics & Sports Medicine

Trabecular metal and non-trabecular metal cups showed no significant difference in survival for hip revisions

Research · J Bone Joint Surg Am · Jan 16, 2026 · Orthopedics & Sports Medicine, Surgery

Assessment of Custom-Made Acetabular Implants for Complex Revision Total Hip Arthroplasty: A Concise Follow-up, at a Minimum of 5 Years

Research · PLOS Med · Nov 26, 2025 · Orthopedics & Sports Medicine

The association between implant design, age, sex and the rate of major reoperation in patients undergoing primary total hip replacement: A retrospective study of UK National Joint Registry and Hospital Episodes Statistics data

Research · PLOS Med · Feb 2, 2026 · Orthopedics & Sports Medicine

Social inequalities in patient outcomes after total hip replacement surgery for osteoarthritis in England: A population-based cohort study of the National Joint Registry