Efficacy of Cylindrical Annular Refractive Elements (CARE) Spectacle Lenses in Slowing Myopia Progression Over 2 Years
Abstract
Purpose
To evaluate over a 2-year period the efficacy of spectacle lenses incorporating cylindrical annular refractive elements (CARE) in slowing myopia progression compared with single vision (SV) spectacle wear. Design
Double-masked, multicenter, randomized clinical trial. Methods
A total of 240 Chinese children aged 6 to 13 years, with a spherical equivalent (SE) refractive error of -0.75 diopters (D) to -5.00 D, were randomized to 1 of 3 groups of SV spectacle lens: CARE spectacles (7-mm central clear zone surrounded by treatment zone incorporating CARE with mean surface power +4.6 D) and CARE S spectacles (9-mm central clear zone surrounded by treatment zone comprising CARE with mean surface power +3.8 D). Cycloplegic SE and axial length (AL) were measured at 6-month intervals. Results
Progression (mean ± SD) in SV-wearing eyes after 24 months of SPL wear was -1.15 ± 0.63 D and 0.59 ± 0.26 mm with SV for SE and AL, respectively. In comparison, myopia progression was significantly slower with both CARE (-0.73 ± 0.63 D/0.40 ± 0.26 mm, P < .0001) and CARE S (-0.80 ± 0.56 D/0.44 ± 0.25 mm, P < .0001). Progression did not differ significantly between CARE lenses. Adjusting for site, group, age, gender, and baseline value at 24 months, CARE showed an absolute difference in SE of 0.44 D (95% CI, 0.21-0.66 D) and CARE S 0.41 D (95% CI, 0.18-0.63D) compared with SV. AL reduction was 0.20 mm (95% CI, 0.10-0.30 mm) with CARE and 0.17 mm (0.07-0.26 mm) with CARE S compared with SV. Conclusions
Over a 2-year period, lenses incorporating CARE significantly slowed myopia progression compared with SV lenses.
Topics
Cite this article
Chen X, Wu M, Yu C, Ohlendorf A, Li W, Liu N. Efficacy of Cylindrical Annular Refractive Elements (CARE) Spectacle Lenses in Slowing Myopia Progression Over 2 Years. Am J Ophthalmol. 2025. doi:10.1016/j.ajo.2025.06.017
Spotted a mistake? Suggest a correction