ReviewAnnals of Internal Medicine · Aug 5, 2025

Engineering Infection Controls to Reduce Indoor Transmission of Respiratory Infections : A Scoping Review

Baduashvili A, Radonovich L, Leslie L, Pease S, Brickson C, Chockalingam L, et al
Infectious DiseaseAdult
Read the full paper free at the publisher ↗

Abstract

Background Engineering infection controls include a wide range of interventions used indoors to reduce occupants' exposure to respiratory pathogens. Purpose To identify and describe primary studies evaluating the effects of engineering infection control interventions designed to reduce the spread of respiratory infections transmitted through indoor air. Data sources MEDLINE, Embase, Global Health, Cochrane Central Register of Controlled Trials, CINAHL, Scopus, and Environmental Science Collection from database inception to 12 December 2023. Study selection English-language primary research articles evaluating engineering infection control interventions. Data extraction Publication information, population characteristics, intervention details, and all relevant outcomes were abstracted by a reviewer and verified by a second, senior reviewer. Data synthesis A total of 672 studies published between 1929 and 2024 were identified. Most (n = 606) evaluated environmental samples only, 57 included human participants, and 9 included sentinel animal subjects. About half of the studies included at least 1 intervention classified as pathogen inactivation (n = 405), with fewer involving pathogen removal (n = 200) or air exchange or dilution (n = 143). Across all studies, about half (n = 332) measured the quantity of viable nonpathogenic organisms from air samples, followed by the quantity of nonbiological particulates (n = 197) or viable pathogenic organisms (n = 149). Harms, such as toxic byproducts, were rarely measured. Limitation Exclusion of non-English-language publications and gray literature. Conclusion There is substantial heterogeneity in the available evidence. Gaps in evidence include studies measuring efficacy outcomes that are highly relevant for human infection transmission or harms. Refinements in classification of interventions and outcomes could strengthen reporting of these evaluations. Primary funding source National Institute for Occupational Safety and Health at the Centers for Disease Control and Prevention. (Registered on Open Science Framework [https://osf.io/5zmhd]).

Subject terms

Respiratory Tract Infections; Humans; Air Pollution, Indoor; Infection Control; Air Microbiology

DOI: 10.7326/ANNALS-25-00577 · PubMed: 40759007

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Baduashvili A, Radonovich L, Leslie L, et al. Engineering Infection Controls to Reduce Indoor Transmission of Respiratory Infections : A Scoping Review. Ann Intern Med. 2025;178(9):1314-1325. doi:10.7326/ANNALS-25-00577

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Infectious Disease studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Research · Lancet Microbe · Jun 4, 2026 · Pediatric · Infectious Disease, Pediatrics

Diversity analysis of indoor and outdoor fungal bioaerosols in UK households: a prospective, observational, longitudinal study

Secondary analysis of a trial n = 200 · JAMA Netw Open · Oct 1, 2025 · Pediatric · Infectious Disease, Pulmonology

Portable air purifiers were not associated with lower odds of high respiratory virus exposure in classrooms

Randomized trial n = 3,717 · JAMA Netw Open · Dec 1, 2022 · Infectious Disease

Wearing glasses in public did not reduce the risk of COVID-19 infection

Research · Emerg Infect Dis · Mar 22, 2026 · Infectious Disease

Environmental and Phylogenetic Investigations of Aspergillus flavus Outbreak Linked to Contaminated Building Materials, Denmark, 2025

Systematic review n = 471 · JAMA Netw Open · Dec 1, 2020 · Infectious Disease

SARS-CoV-2 RNA was found in 17.4% of hospital air samples in a systematic review